SIPLACE D4-D4i 工程师手册_EN - 第36页
Overview Component Handling 3.4.1 Changeover Table 36 Service Manual SIPLACE D4/D4i 3.4 3 . 4 C o m p o n e n t H a n d lin g Component Handling 3.4.1 3 . 4 . 1 C h a n g e o v e r T a b le Changeover Table 3.4.1.1 3 . 4…

Overview
3.3.1 Parts Overview Gantry
Service Manual SIPLACE D4/D4i 35
Gantry - parts overview 2
Legend
Gantry - parts overview 3
Legend
The compressed air distributor (2), gantry distributor (3) and hotlink card (4) are located under the cover
(1).
1 Elastomeric spring 25x10.5x50 (90 Shore
A) [00301040-01]
2 X axis scale [00329316-01]
3 Deflection unit X [00330938-02]
1 Cover 3 Gantry distributor
2 Compressed air distributor 4 Hotlink card

Overview
Component Handling 3.4.1 Changeover Table
36 Service Manual SIPLACE D4/D4i
3.4
3.4 Component Handling
Component Handling
3.4.1
3.4.1 Changeover Table
Changeover Table
3.4.1.1
3.4.1.1 Structure of Changeover Table (S Table)
Structure of Changeover Table (S Table)
Component trolley – front and back view
Legend
1. Movable base
2. Tape reels container
3. Handles
4. Tape waste container
5. Communication unit; the splice detection unit option
is fitted under the communication unit
6. Changeover table
7. Switch for lowering the changeover table
8. Pockets for the setup list printouts
9. Voltage 30 V communication unit (yellow LED)

Overview
3.4.2 Cutter Component Handling
Service Manual SIPLACE D4/D4i 37
3.4.2
3.4.2 Cutter
Cutter
3.4.2.1
3.4.2.1 Safety Instructions
Safety Instructions
DANGER
The safety instructions in the chapter "Operational Safety" in the operating manual and this ser-
vice manual take priority.
The machine is supplied with
219/380 V +/- 5% or
230/400 V +/- 5% or
239/415 V +/- 5% or
117/204 V +/- 5% or
133/230 V +/- 5%,
50/60 Hz mains voltage.
Inside the machine base this is true even while the master switch is turned off.
► The machine has to be switched OFF and disconnected from the line before you perform
any work in the area of the cutter.
► In addition, the compressed air supply must be turned off at the main valve of the com-
pressed air unit in the machine base and the compressed air lines must be bled by actuating
the needle valve on the compressed air unit.
WARNING
► Wear appropriately thick protective gloves when working near the blades/the tape deflector!
► There is a high risk of injury from stationary blades and moveable blades and from the tape
deflector of the cutter, even when the machine has been turned off!