SIPLACE D4-D4i 工程师手册_EN - 第80页
Service Work Component Handling 4.3.2 Cutter 80 Service Manual SIPLACE D4/D4i ► After exchanging the cable for t he change over table and/or the com munications unit: Note the DANGER text regard ing the S ITEST program .…

Service Work
4.3.1 Changeover Table Component Handling
Service Manual SIPLACE D4/D4i 79
Cable for changeover table (D4 shown as example)
► Feed the new cable into the cord grip from the top to the bottom.
► Plug in the communication unit connection cable and reconnect the pneumatic system.
► Run the cable and attach cable ties.
► If you have no further parts to be exchanged, perform the appropriate "Final Steps", including a table
function check with SITEST.
See also
4.3.1.6 Final Steps [ ➙ 79]
4.3.1.6
4.3.1.6 Final Steps
Final Steps
► Check the contact surface for the feeder modules on the changeover table:
If necessary, clean the surface, as described in the User Manual in chapter "Maintenance".
► Place the feeder modules incl. the tape reels in the right order on the changeover table (in accord-
ance with the specifications for setup optimization).
If an external setup location is available, perform the setup there, incl. inserting the tapes and check-
ing the allocations „Feeder module / track“ and „Component/ track“.
► Connect all feeder modules to the relevant jack of the communications unit (changeover table termi-
nation panel).
► Switch the machine on. The compressed air is attached. Move the changeover table back into the
machine and connect it. To do this, plug in the changeover table and lower it onto the changeover
table rest and centering point.
Perform the steps in the correct order!
► Make sure that the changeover table has been correctly inserted into the machine!
► Reconnect to the power supply supply.
► If this has not been done yet, insert the tapes now and check the allocation of feeder module and
component (component bar code scanner).
► Step / transport the first component into the pickup position. VISUALLY CHECK the front of the mod-
ule to see if all tapes move smoothly into the empty-tape duct.
DANGER
Guard (dummy module)
The changeover table, which has been moved into the machine, must always be completely
equipped with feeder modules or dummy modules (see User Manual and Service Manual,
chapters " "Operational Safety").
DANGER
The SITEST program may only be started by personnel who have been trained in its use by
Siemens and are therefore authorized to do so.
► The cutter must also be completely assembled for work with the SITEST program. The
changeover table must be moved into the machine and docked correctly.
► The changeover table, which has been moved into the machine, must always be completely
equipped with feeder modules or dummy modules (see User Manual and Service Manual,
chapters " "Operational Safety").

Service Work
Component Handling 4.3.2 Cutter
80 Service Manual SIPLACE D4/D4i
► After exchanging the cable for the changeover table and/or the communications unit:
Note the DANGER text regarding the SITEST program.
Load the SITEST program and check the changeover table functions.
► Exit the SITEST program.
► Start the placement process.
4.3.2
4.3.2 Cutter
Cutter
4.3.2.1
4.3.2.1 Safety Instructions
Safety Instructions
4.3.2.2
4.3.2.2 Parts
Parts
All spare parts, plus the corresponding diagrams and article numbers, can be found in the D4 spare parts
catalogue.
See also
4.3.2.4 Overview of Cutter [ ➙ 82]
4.3.2.3
4.3.2.3 Tools, Expendable Materials, Documentation
Tools, Expendable Materials, Documentation
▪ Thick protective gloves
▪ Set of socket wrenches, cross-slotted screwdriver size 4
▪ Open-end wrench, width across flats 10; 1
▪ Torque wrench, Diagonal cutter, Sliding caliper
▪ Feeler gauge: 0.05mm; 1.0mm; 1.5mm; 2.0mm; 2.50 mm
▪ Straight-edge (for check of tape deflector)
DANGER
The safety instructions in the chapter "Operational Safety" in the operating manual and this ser-
vice manual take priority.
The machine is supplied with
219/380 V +/- 5% or
230/400 V +/- 5% or
239/415 V +/- 5% or
117/204 V +/- 5% or
133/230 V +/- 5%,
50/60 Hz mains voltage.
Inside the machine base this is true even while the master switch is turned off.
► The machine has to be switched OFF and disconnected from the line before you perform
any work in the area of the cutter.
► In addition, the compressed air supply must be turned off at the main valve of the com-
pressed air unit in the machine base and the compressed air lines must be bled by actuating
the needle valve on the compressed air unit.
WARNING
► Wear appropriately thick protective gloves when working near the blades/the tape deflector!
► There is a high risk of injury from stationary blades and moveable blades and from the tape
deflector of the cutter, even when the machine has been turned off!
NOTICE
This manual applies for the pneumatic cutter version 04 and the corresponding empty tape duct
version 03.
Version 04 of the cutter contains, for example, a tape deflector for the tapes, which is fitted
above the moveable blades.
Service Work
4.3.2 Cutter Component Handling
Service Manual SIPLACE D4/D4i 81
▪ Mounting plate [00312731-01]
▪ 2 large parallel clamps (or mounting plate, see above)
▪ Flat, sturdy work bench to fasten the removed cutter (or mounting plate, see above)
▪ Loctite No. 234 [00334892-01]
▪ Molykote paste 250 g [02100335-01] (recommended) or ISOFLEX TOPAS NCA 52 tube 50g
[00330850-01]
▪ Water-insoluble, fine-tip marker and
▪ a dry and clean cloth
▪ Current SIPLACE D4 spare parts catalogue and SIPLACE D4 circuit diagrams
▪ SITEST program and current SITEST operating manual
See also