1-125 System Messages of the MMI and Solutions  The foreign matter is recognized as lead .  The component size was inputted incorrect ly . [Solution]  Perform [Solution] in $a635. $a637 There isn’t boundary(%d) at the…

100%1 / 204
1-124
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
The component was not picked up actually.
Lighting level was setup too dark.
The component size was inputted incorrectly.
[Solution]
The component size was inputted incorrectly.
Perform [Solution] in $a610.
$a634 There isn’t bright(%d) pixel on the first(upper side)lead of right lead group.
[Problem]
The lead was not recognized when recognizing the component lead.
The component was not picked up actually.
Lighting level was setup too dark.
The component size was inputted incorrectly.
[Solution]
Check if the component was actually picked up.
Perform [Solution] in $a610.
$a635 There isn’t boundary(%d) at the first(left side) upper lead of lead group.
[Problem]
The lead was not recognized when recognizing lead of the component first.
The component was not picked up actually.
Lighting level was setup too dark or too bright.
The foreign matter is recognized as lead.
The component size was inputted incorrectly.
[Solution]
Check if the component is actually picked up.
If there is any foreign matter between nozzle and mirror or between leads, please
remove it. For the method to remove foreign matter from the nozzle, please refer to
Checking and cleaning the nozzle” in the “Maintenance Handbook”.
Perform [Solution] in $a610.
$a636 There isn’t boundary at the first(upper side)lead of left lead group.
[Problem]
The lead was not recognized when recognizing lead of the component first.
The component was not picked up actually.
Lighting level was setup too dark or too bright.
1-125
System Messages of the MMI and Solutions
The foreign matter is recognized as lead .
The component size was inputted incorrectly.
[Solution]
Perform [Solution] in $a635.
$a637 There isn’t boundary(%d) at the first(left side)lead of lower lead group.
[Problem]
The lead was not recognized when recognizing lead of the component first.
The component was not picked up actually.
Lighting level was setup too dark or too bright.
The foreign matter is recognized as lead.
The component size was inputted incorrectly.
[Solution]
Perform [Solution] in $a635.
$a638 There isn’t boundary(%d) at the first(upper side)lead of right lead group.
[Problem]
The lead was not recognized when recognizing lead of the component first.
The component was not picked up actually.
Lighting level was setup too dark or too bright.
The foreign matter is recognized as lead.
The component size was inputted incorrectly.
[Solution]
Perform [Solution[Solution]] in $a635.
$a641 There is a bright pixel outside the first(left side) lead of upper lead group.
[Problem]
The lead of component was recognized, but other thing was recognized outside of the
lead.
The mirror is contaminated with foreign matter.
The nozzle is contaminated with foreign matter or its coating was peeled off.
Component data and lighting is inadequate.
[Solution]
Perform [Solution] in $a635.
1-126
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
$a642 There is bright pixel at the first(upper side) lead of left lead group.
[Problem]
The lead of component was recognized, but other thing was recognized outside of the
lead.
The mirror is contaminated with foreign matter.
The nozzle is contaminated with foreign matter or its coating was peeled off.
Component data and lighting is inadequate.
[Solution]
Perform [Solution] in $a635.
$a643 There is bright pixel outside of the first(left side) lead of lower lead group.
[Problem]
The lead of component was recognized, but other thing was recognized outside of the
lead.
The mirror is contaminated with foreign matter.
he nozzle is contaminated with foreign matter or its coating was peeled off.
Component data and lighting is inadequate.
[Solution]
Perform [Solution] in $a635..
$a644 There is bright pixel outside of the first(left side) lead of lower lead group.
[Problem]
The lead of component was recognized, but other thing was recognized outside of the
lead.
The mirror is contaminated with foreign matter.
he nozzle is contaminated with foreign matter or its coating was peeled off.
Component data and lighting is inadequate.
[Solution]
Perform [Solution] in $a635.
$a645 Boundary at the first(left side) lead of upper lead group is small.
[Problem]
Length of the component lead is recognized too short.
Lead of the component is actually defective.
False recognition of foreign matter as lead.
The component data and lighting setup is inadequate.