1-128 Next Generation, Multi-Functional Plac er DECAN S1 Troubleshooting Guide Recognized the co mponent lead is seriously damaged. The component lead is defective. The component lead does not look uniform. [Soluti…

1-127
System Messages of the MMI and Solutions
[Solution]
The component data and lighting setup is inadequate.
Perform [Solution] in $a635.
$a646 Boundary at the first(upper side) lead of left side lead group is small.
[Problem]
Length of the component lead is recognized too short.
Lead of the component is defective.
False recognition of foreign matter as lead.
False recognition of foreign matter as lead.
[Solution]
Check if the lead is defective.
Perform [Solution] in $a635.
$a647 Boundary at the first(left side) lead of the lower lead group is small.
[Problem]
Length of the component lead is recognized too short.
Lead of component is defective.
False recognition of foreign matter as lead.
Component data and lighting setup is inadequate.
[Solution]
Check if the lead is defective.
Perform [Solution] in $a635.
$a648 Boundary at the first(upper side) lead of right side lead group is small.
[Problem]
Length of the component lead is recognized too short.
Lead of the component is defective.
False recognition of foreign matter as lead.
The component data and lighting setup is inadequate.
[Solution]
Check if the lead is defective.
Perform [Solution] in $a635.
$a649 First(left side) lead of upper lead group is a not straight line.
[Problem]

1-128
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
Recognized the component lead is seriously damaged.
The component lead is defective.
The component lead does not look uniform.
[Solution]
Check if the component lead is actually defective.
If leads of a component do not appear uniform, perform recognition by selecting the
‘Fix Camera’ as a camera for recognizing components.
$a64a First(upper side) lead of left side lead group is not straight.
[Problem]
The component lead is recognized to have been damaged seriously.
The component lead is defective.
The component lead does not look uniform.
[Solution]
Check if the component lead is defective.
If leads of a component do not appear uniform, perform recognition by selecting the
‘Fix Camera’ as a camera for recognizing components.
$a64b First(left side) lead of lower lead group is not straight.
[Problem]
The component lead is recognized to have been damaged seriously.
The component lead is defective.
The component lead does not look uniform.
[Solution]
Check if the component lead is actually defective.
If leads of a component do not appear uniform, perform recognition by selecting the
‘Fix Camera’ as a camera for recognizing components.
$a64c First(upper side) lead of right lead group is not straight.
[Problem]
The component lead is recognized to have been damaged seriously.
The component lead is actually defective
The component lead does not look uniform.
[Solution]
Check if the component lead is actually defective.

1-129
System Messages of the MMI and Solutions
If leads of a component do not appear uniform, perform recognition by selecting the
‘Fix Camera’ as a camera for recognizing components.
$a651 There isn’t bright(%d) pixel at the final(left side)lead of upper lead group.
[Problem]
The position where the component should have been looks black.
The component lead is actually defective
Mirror is contaminated with foreign matter
There is foreign matter on the nozzle or the nozzle is peeled off
The component data and lighting setup is inadequate.
[Solution]
Check if the component lead is actually defective.
Perform [Solution] in $a635.
$a652 There isn’t bright(%d) pixel at the final(upper side)lead of left side lead group.
[Problem]
The position where the component should have been looks black.
The component lead is actually defective.
Mirror is contaminated with foreign matter.
There is foreign matter on the nozzle or the nozzle coating is peeled off.
The component data and lighting setup is inadequate.
[Solution]
Check if the component lead is actually defective.
Perform [Solution] in $a635.
$a653 There isn’t bright(%d) pixel at the final(left side) lead of lower lead group.
[Problem]
Position of component lead looks black.
The component lead is actually defective.
Mirror is contaminated with foreign matter.
There is foreign matter on the nozzle or nozzle coating is peeled off.
The component data and lighting setup is inadequate.
[Solution]
Check if the component lead is actually defective.
Perform [Solution] in $a635.