DECAN_S1_Troubleshooting_Guide(Eng_Ver1.3)_Print_Web.pdf - 第153页
1-129 System Messages of the MMI and Solutions If leads of a component do not appear unif orm, perform recognition by selecting the ‘Fix Camera’ as a camera for recognizing components. $a651 There isn’t bright(%d) pixe…

1-128
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
Recognized the component lead is seriously damaged.
The component lead is defective.
The component lead does not look uniform.
[Solution]
Check if the component lead is actually defective.
If leads of a component do not appear uniform, perform recognition by selecting the
‘Fix Camera’ as a camera for recognizing components.
$a64a First(upper side) lead of left side lead group is not straight.
[Problem]
The component lead is recognized to have been damaged seriously.
The component lead is defective.
The component lead does not look uniform.
[Solution]
Check if the component lead is defective.
If leads of a component do not appear uniform, perform recognition by selecting the
‘Fix Camera’ as a camera for recognizing components.
$a64b First(left side) lead of lower lead group is not straight.
[Problem]
The component lead is recognized to have been damaged seriously.
The component lead is defective.
The component lead does not look uniform.
[Solution]
Check if the component lead is actually defective.
If leads of a component do not appear uniform, perform recognition by selecting the
‘Fix Camera’ as a camera for recognizing components.
$a64c First(upper side) lead of right lead group is not straight.
[Problem]
The component lead is recognized to have been damaged seriously.
The component lead is actually defective
The component lead does not look uniform.
[Solution]
Check if the component lead is actually defective.

1-129
System Messages of the MMI and Solutions
If leads of a component do not appear uniform, perform recognition by selecting the
‘Fix Camera’ as a camera for recognizing components.
$a651 There isn’t bright(%d) pixel at the final(left side)lead of upper lead group.
[Problem]
The position where the component should have been looks black.
The component lead is actually defective
Mirror is contaminated with foreign matter
There is foreign matter on the nozzle or the nozzle is peeled off
The component data and lighting setup is inadequate.
[Solution]
Check if the component lead is actually defective.
Perform [Solution] in $a635.
$a652 There isn’t bright(%d) pixel at the final(upper side)lead of left side lead group.
[Problem]
The position where the component should have been looks black.
The component lead is actually defective.
Mirror is contaminated with foreign matter.
There is foreign matter on the nozzle or the nozzle coating is peeled off.
The component data and lighting setup is inadequate.
[Solution]
Check if the component lead is actually defective.
Perform [Solution] in $a635.
$a653 There isn’t bright(%d) pixel at the final(left side) lead of lower lead group.
[Problem]
Position of component lead looks black.
The component lead is actually defective.
Mirror is contaminated with foreign matter.
There is foreign matter on the nozzle or nozzle coating is peeled off.
The component data and lighting setup is inadequate.
[Solution]
Check if the component lead is actually defective.
Perform [Solution] in $a635.

1-130
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
$a654 There isn’t bright(%d) pixel at the final(upper side)lead of right side lead group.
[Problem]
Position of component lead looks black.
The component lead is actually defective.
Mirror is the contaminated with foreign matter.
There is foreign matter on the nozzle or nozzle coating is peeled off.
The component data and lighting setup is inadequate.
[Solution]
Check if the component lead is actually defective.
Perform [Solution] in $a635.
$a660 Can not find any lead while recognizing %d direction lead group(%d).
[Problem]
There is no lead in the lead group recognition range.
The component is defective in size.
The component data or lighting setup is inadequate.
[Solution]
Check if the component size is actually defective.
Perform [Solution] in $a610.
$a665 Recognized number(%d) of lead of %d direction lead group(%c) is different from the
registered number of lead(%d).
[Problem]
Registered number of leads for the component is different from the recognized number
of leads.
The component lead is defective.
Incorrect registration the number of leads in the component data.
The component data and lighting setup is inadequate.
[Solution]
The component data and lighting setup is inadequate.
Perform [Solution] in $a610.
$a671 Failure to locate the end pin of the upper lead group.
[Problem]
Failed in detailed recognition of component lead.
Failed in detailed recognition of component lead.