$a831 Background of image is too bright.
[Problem]
Lighting is set up too bright.
Foreign matter other than the component is recognized in the vision.
[Solution]
Perform [Solution] in $a635.
$a832 The component looks too dark.
[Problem]
$a832The component looks too dark.
[Solution]
Select the error occurred component in “Part” of the “PCB Edit” menu and check the
illumination setup in the Profile Editor. Please refer to the [Solution] in $a610.
$a833 Can not find the boundary line of the component.
[Problem]
$a833Can not find the boundary line of the component.
[Solution]
Select the error occurred component in “Part” of the “PCB Edit” menu and check the
illumination setup in the Profile Editor. Please refer to the [Solution] in $a610.
$a842 Failed in retrieving the first pin between the pins at both ends of lead group.
[Problem]
Failed in detailed recognition of lead.
The component lead is defective.
Lighting setup of the component data is inadequate.
[Solution]
Check if the component is defective.
Perform [Solution] in $a610.
$a843 Failed in retrieving the last pin between the pins at both ends of lead group.
[Problem]
Failed in detailed recognition of lead.
The component lead is defective.
Lighting setup of the component data is inadequate.
[Solution]
1-135
System Messages of the MMI and Solutions
Check if the component is defective.
Perform [Solution] in $a610.
$a844 Number of pins of recognized lead group is too few.(Less than 4)
[Problem]
Number of recognized pins is too few(Less than 4).
The component lead is defective.
The component data and lighting setup is inadequate.
[Solution]
Register the components with less than 4 leads as Tr.
Check if the component is actually defective.
Perform [Solution] in $a610.
$a845 There isn’t a pin which should be in the lead group.
[Problem]
Numbers of recognized lead registered lead are different.
The component lead is defective.
The component data or lighting setup is inadequate.
[Solution]
Register the components with less than 4 leads as Tr.
Check if the component is actually defective.
Perform [Solution] in $a610.
$a846 Pitch of lead group is off the allowable value.
[Problem]
The values of pitch recognized by vision and registered one are different.
Lead of the component is bent.
Pitch value of the component was inputted incorrectly.
Pitch value of the component was inputted incorrectly.
[Solution]
Check if the lead of the component is bent.
Perform [Solution] in $a610.
$a847 Cannot find the boundary line for searching the pin of lead group.
[Problem]
Can not recognize the lead while recognizing the lead.
1-136
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
The lighting is set up too bright or too dark.
Foreign matter other than the component is recognized by the vision.
[Solution]
Foreign matter other than the component is recognized by the vision.
$a848 Among the recognized parameters, the width and foot are too large.
[Problem]
The width and foot length of recognized lead is too large.
The component data and lighting setup is inadequate.
[Solution]
Perform [Solution] in $a610.
$a851 Too many objects have been filtered.
[Problem]
Too many foreign matters other than the component have been recognized.
The component data and lighting setup is inadequate.
[Solution]
Perform [Solution] in $a635.
$a852 Code length has exceeded the maximum length.
[Problem]
The shape of the component is too complicated.
The component data or lighting setup is inadequate.
[Solution]
When the shape of the component is too complicated, register in other type.
When the shape of the component is too complicated, register in other type.
$a860 An error occurred while executing the MinWidth algorithm.
[Problem]
An error occurred due to H/W problem or S/W problem.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$aa04 Can not find the components.
[Problem]
The component was not actually picked up.