1-138 Next Generation, Multi-Functional Plac er DECAN S1 Troubleshooting Guide $aa09 Center of the component is offset too much. $aa0a Center of the component is offset too much. [Problem]  The componen t is too much of…

100%1 / 204
1-137
System Messages of the MMI and Solutions
The threshold value of the component is setup too high.
[Solution]
Check the pickup position of the corresponding component through the SMVision
window in the Feeder of “PCB Edit” menu, and verify if the feeder is correctly
installed in the slot.
In “Part” of the “PCB Edit” menu, setup the threshold value of the error occurred
component to be lower than the component. As the threshold value is setup
automatically, do not select the <Auto> check box to change the value manually.
For more details, please refer to “7.1 New Components Registration” in the
“Administrator’s Guide”
$aa07 Size of the component has been recognized differently.
[Problem]
The component was not picked up correctly.
The ‘Body X’ of the component was incorrectly inputted.
The tolerance for H and L of the component were setup too small
Foreign matter is in the nozzle.
[Solution]
Check if the component is correctly picked up.
Select the error occurred component in “Part” of the “PCB Edit” menu, and check if
the ‘Body X’ at ‘Profile Editor’ has been correctly input.
Select the error occurred component in “Part” of the “PCB Edit” menu, and check if
the ‘Body X’ at ‘Profile Editor’ has been correctly input.
Remove foreign matter from the nozzle, if any.
Please refer to the [Solution] in $a635.
$aa08 The component size was recognized differently.
[Problem]
The component was not picked up.
Incorrect input of ‘Body Y’ of the component.
The tolerance of H and L of the component is set up too low.
The nozzle is contaminated with foreign matter.
[Solution]
Perform [Solution] in $aa07.
1-138
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
$aa09 Center of the component is offset too much.
$aa0a Center of the component is offset too much.
[Problem]
The component is too much offset from the center of nozzle when picking up the
component.
The fly camera shook when mounting the component.
[Solution]
Check if the components are correctly picked up.
Check the pickup position of the corresponding component through the SMVision
window in the Feeder of the “PCB Edit” menu, and verify if the feeder is correctly
installed in the slot.
If the problem continues to occur even while the components are normally picked up,
check if the camera is shaked.
And, perform the camera calibration by selecting the ‘Calib’ submenu of the ‘Sys.
Setup’ menu and clicking the <Head & Camera Calibration> button.
please refer to “12.3.10 Head & Camera Calibration” in the “Administrator’s Guide”
section.
$aa0b Angle of the component is off the reference angle.
[Problem]
Angle of the component rotated too much when picking up the component.
[Solution]
Readjust the pickup position of the error occurred component in “Feeder” of the “PCB
Edit” menu, or reduce the component pickup speed in the “Common Data”.
$aa0c Internal function Error(MelfFindOut).
[Problem]
An error occurred during component recognition.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$aa0d Internal function Error(MelfAreaSort).
[Problem]
An error occurred during component recognition.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system..
1-139
System Messages of the MMI and Solutions
$aa0e Size of the component is too small.
[Problem]
The size of the component is too small for the camera to recognize.
[Solution]
Check the smallest component size that can be recognized in the present camera, and
recognize the corresponding component using a camera with less FOV. (in the case of
the camera with the 16FOV, reduce it to the mega 16FOV)
$aa0f Height of the component lead was recognized less.
[Problem]
The component was not picked up correctly.
Incorrect input of ‘Body Y’ of the component.
Incorrect input of ‘Body Y’ of the component.
The nozzle is contaminated with foreign matter.
[Solution]
Check if the component was correctly set up.
Select the error occurred component in “Part” of the “PCB Edit” menu, and check if
the ‘Body Y’ at ‘Profile Editor’ has been correctly input.
Select the error occurred component in “Part” of the “PCB Edit” menu, and enter 30%
as the tolerance L in the ‘Profile Editor’.
Remove foreign matter from the nozzle, if any.
Please refer to the [Solution] in $a635.
$aa10 Height of the component lead was recognized higher.
[Problem]
The component was not picked up correctly.
Incorrect input of ‘Body Y’ of the component.
The tolerance L of the component was set up too low.
The tolerance L of the component was set up too low.
[Solution]
Check if the component was correctly picked up.
Select the error occurred component in “Part” of the “PCB Edit” menu, and check if
the ‘Body Y’ at ‘Profile Editor’ has been correctly input.
Select the error occurred component in “Part” of the “PCB Edit” menu, and enter 30%
as the tolerance H in the ‘Profile Editor’.
Remove foreign matter from the nozzle, if any.