1-148 Next Generation, Multi-Functional Plac er DECAN S1 Troubleshooting Guide $ab24 Undefined algorithm. [Problem]  An incorrect result has been received from the VME. [Solution]  T urn off power to the machine in the…

100%1 / 204
1-147
System Messages of the MMI and Solutions
If a component is not picked up, assign the component pickup position again at the
PCB edit feeder of the MMI. Through the SMVision window, check the pickup
position of the corresponding component in “Feeder” of the “PCB Edit” menu.
Check if the lead of the picked up component is bent.
Select the error occurred component in “Part” of the “PCB Edit” menu and verify in
the “Profile Editor” if lead information (lead width, lead pitch) is correctly input.
$ab20 Internal function Error(TrCenterCorrection).
[Problem]
An error occurred during component recognition.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$ab21 Total number of leads is less than two.
[Problem]
The sum of the upper leads and lower leads is less than two.
Recognition is impossible when the sum of leads is less than two.
[Solution]
Select the error occurred component in “Part” of the “PCB Edit” menu, check the
“Lead Num” on the “Profile Editor”, and input the accurate number of leads.
$ab22 Total number of leads is too many.
[Problem]
Total number of upper leads and lower leads is more than 30.
Recognition is impossible when the sum of leads is more than 30.
[Solution]
Select the error occurred component in “Part” of the “PCB Edit” menu, check the
“Lead Num” on the “Profile Editor”, and input the accurate number of leads.
$ab23 Number of leads is a minus value.
[Problem]
Received incorrect value from the VME.
The lead number is inputted in a minus value.
[Solution]
Select the error occurred component in “Part” of the “PCB Edit” menu, check the
“Lead Num” on the “Profile Editor”, and input the accurate number of leads.
1-148
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
$ab24 Undefined algorithm.
[Problem]
An incorrect result has been received from the VME.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$ab25 Undefined angle.
[Problem]
An incorrect result has been received from the VME.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$ab26 Error occurred while inspecting leads.
[Problem]
Did not pickup the component.
Lead of the component is bent too much.
Incorrect input of lead information.
[Solution]
Perform [Solution] in $aa1f.
$ab27 Error occurred while inspecting leads.
[Problem]
The component was not picked up.
The lead of the component is bent too much.
Incorrect input of the lead information.
[Solution]
Perform [Solution] in $aa1f.
$ab28 Error occurred while inspecting leads.
[Problem]
The component was not picked up.
The lead of the component is bent too much.
Incorrect input of the lead information.
[Solution]
1-149
System Messages of the MMI and Solutions
Perform [Solution] in $aa1f.
$ab29 Error occurred while inspecting leads.
[Problem]
The component was not picked up.
The lead of the component is bent too much.
Incorrect input of the lead information.
[Solution]
Perform [Solution] in $aa1f.
$ab2b Angle of the component has deviated from the reference value.
[Problem]
Angle of the component has been rotated too much when picking up the component.
[Solution]
If a component is not picked up, assign the component pickup position again at the
PCB edit feeder of the MMI. Through the SMVision window, check the pickup
position of the corresponding component in “Feeder” of the “PCB Edit” menu.
Check if selection of the nozzle is correct.
$ac00 Incorrect angle number has been transmitted from the VME.
[Problem]
An incorrect angle method has been transmitted from the VME.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$ac02 Input of incorrect parameter.
[Problem]
Input of the incorrect value of the component parameter.
[Solution]
Check the parameter of the corresponding component on the ‘Part’ of the PCB Edit
menu.
$ac07 The recognized width of the component was different from the reference value.
[Problem]
Incorrect input of the ‘Body X of the component.
The tolerance for H and L of the component was set too low.