DECAN_S1_Troubleshooting_Guide(Eng_Ver1.3)_Print_Web.pdf - 第181页

1-157 System Messages of the MMI and Solutions $ad22 During au to teaching, an error of negat ive number for the reco gnized component size (%d) occurred. [Problem]  An error occurred due to H/W pro blem or S/W problem.…

100%1 / 204
1-156
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
$ad18 There is big difference in the radial distance(%d, %d) of the lead groups(%d, %d)
facing each other when performing ‘Auto Teach’.(Allowable value %d)
[Problem]
Lead group of the component is asymmetrical.
Lighting setup is inadequate.
[Solution]
In the case of the asymmetrical component, register it manually.
Select the error occurred component in “Part” of the “PCB Edit” menu and check that
illumination is correctly setup in the “Profile Editor”.
$ad19 The difference in value between the recognized lead parameters is big during ‘Auto
Teach’.
[Problem]
The Lead parameter values of the recognized lead groups are different.
The lead group of the components is asymmetrical.
Lighting setup is inadequate.
[Solution]
In the case of the asymmetrical component, register it manually.
Select the error occurred part from ‘Part’ of the PCB Edit menu and set the
illumination so that all lead groups are evenly illuminated.
$ad20 During auto teaching, the recognized foot length (%d) of the lead group %d is less
than the lead length (%d).
[Problem]
An error occurred due to H/W problem or S/W problem.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$ad21 During auto teaching, the recognized pitch (%d) of the lead group %d is less than the
lead width (%d).
[Problem]
An error occurred due to H/W problem or S/W problem.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
1-157
System Messages of the MMI and Solutions
$ad22 During auto teaching, an error of negative number for the recognized component size
(%d) occurred.
[Problem]
An error occurred due to H/W problem or S/W problem.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$ad30 The difference in recognized width values(%d, %d) of lead group(%d, %d) is big
when performing ‘Auto Teach’.
[Problem]
The difference in the recognized lead width between two lead groups is big.
Lead group of the component is asymmetrical.
Lighting setup is inadequate.
[Solution]
In the case of the asymmetrical component, register it manually.
Select the error occurred part from ‘Part’ of the PCB Edit menu and set the
illumination so that all lead groups are evenly illuminated.
$ad31 The difference in the recognized length(%d, %d) of the lead groups(%d, %d) is big
when performing ‘Auto Teach’.(Allowable value: %d)
[Problem]
The difference in the recognized lead width between two lead groups is big.
The lead group of the components is asymmetrical.
Lighting setup is inadequate.
[Solution]
In the case of the asymmetrical component, register it manually.
Select the error occurred part from ‘Part’ of the PCB Edit menu and set the
illumination so that all lead groups are evenly illuminated.
$ad32 Difference between the recognized pitch(%d, %d) of lead groups(%d, %d) during
‘Auto Teach’ is big.(Allowable value: %d)
[Problem]
The difference in the recognized lead pitch between two lead groups is big.
The lead group of the components is asymmetrical.
Lighting setup is inadequate.
[Solution]
1-158
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
In the case of the asymmetrical component, register it manually.
Select the error occurred part from ‘Part’ of the PCB Edit menu and set the
illumination so that all lead groups are evenly illuminated.
$ad33 The difference in the recognized foot value(%d, %d) between the lead groups(%d,
%d) when performing ‘Auto Teach’ is big.(Allowable value: %d)
[Problem]
The difference in the recognized lead foot between two lead groups is big.
The lead group of the components is asymmetrical.
Lighting setup is inadequate.
[Solution]
In the case of the asymmetrical component, register it manually.
Select the error occurred part from ‘Part’ of the PCB Edit menu and set the
illumination so that all lead groups are evenly illuminated.
$ae03 Failed in recognizing the fiducial mark.
[Problem]
The fiducial mark was not recognized.
The fiducial mark is not within the range of recognition, or defective.
The fiducial data or lighting setup is inadequate.
[Solution]
Check fiducial data and lighting setup, and readjust them. Please refer to section “6.3
Fiducial Mark Setup” of the Administrator’s Guide.
1.4.12. Software debug Related Error [$b000~$bfff]
$bbbb Assert fault has occurred. [MPU_STOP LEVEL]
[Problem]
An assert fault has occurred due to H/W problem or S/W problem.
[Solution]
Turn off power to the machine in the usual way. Wait 5 seconds, turn back on and
reboot the system.
$bc00 Equipment is not ready. [FREEZE LEVEL]
[Problem]
This error occurs when the equipment is driven without pressing the ready switch.
[Solution]