1-15 System Messages of the MMI and Solutions E0120 The XY coordinates of the corresponding spindle center become incorrect due to a deformed ball spline [Cause] Deformed ball spline [Measures] Check the run-out stat…

1-14
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
Defective head I/O board operation
[Measures]
Change the head I/O board and check whether it operates properly. Contact our
designated C/S company or local agent.
E0106 Abnormal vacuum generation due to a defective vacuum sensor board
[Cause]
Defective vacuum sensor board operation
[Measures]
Change the vacuum sensor board and check whether it operates properly. Contact our
designated C/S company or local agent.
E0107 Low vacuum pressure due to air leak
[Cause]
Air leaks from the Rotary Joint, Coil Tube, Vacuum Sensor Board, tube Fittings, etc.
Check whether noise is generated
[Measures]
Check the air leaking point listening to the air leaking sound. If it is necessary to
replace a part, contact our designated C/S company or local agent. (Replace rotary
joint, coil tube, tube fittings, etc.)
E0108 Overall low vacuum pressure due to defective setup of the main pneumatic pressure
[Cause]
Incorrect setup of the main air regulator of the machine (0.45~0.55Mpa)
[Measures]
Set the pneumatic pressure again. (0.5 MPa)
E0109 Low vacuum pressure due to a defective blow gauge setup
[Cause]
Defective blow gauge setup (1 bar)
[Measures]
Set the pneumatic pressure again. (1 bar)
E0110 Delayed vacuum generation due to a defective vacuum delay setup
[Cause]
Check the Vac. Delay
[Measures]
Set the Vac. Delay again.

1-15
System Messages of the MMI and Solutions
E0120 The XY coordinates of the corresponding spindle center become incorrect due to a
deformed ball spline
[Cause]
Deformed ball spline
[Measures]
Check the run-out state of the ball spline after removing the nozzle holder. If
necessary, reassemble the ball spline or perform calibration. Contact our designated C/
S company or local agent. (Replace ball spline )
E0121 Incorrect setup of the XY coordinates of the pickup point
[Cause]
Incorrect pickup position setup in the 'Feeder' menu of the MMI
[Measures]
Teach the part pickup position of the feeder again.
E0122 Incorrect tape guide position causes interference during feeding
[Cause]
1) The tape guide is not secured correctly with a locker.
2) There is foreign material on the vinyl contact surface of the tape guide.
3) The tape guide is deformed due to collision or is worn out.
[Measures]
1) Secure the tape guide with locker correctly
2) Clean the tape guide periodically.
3) Contact our designated C/S company or local agent for proper measures.
E0123 The part feeding position becomes incorrect due to incorrect tape splicing caused by
a splicing error
[Cause]
Wrong tape splicing due to incorrect tape reel splicing.
[Measures]
Splice the vinyl using the vinyl splicing tape and splicing tip provided by Hanwha
Precision Machinery Co., Ltd. and splice the tape reel again properly. (Refer to the
tape feeder manual)
E0124 The Y part feeding position is incorrect when installing tape
[Cause]
The Y coordinate for pickup has deviated since there is a part or foreign material on
the reference surface of the tape feeder.

1-16
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
[Measures]
Remove the part or foreign materials.
E0125 The X part feeding position is incorrect due to a problem with the feeder
[Cause]
Incorrect X pickup position of the tape feeder
[Measures]
Adjust the X pickup position of the tape feeder using the calibration jig provided by
Hanwha Precision Machinery Co., Ltd..
E0126 Incorrect setup of the part feeding position of the feeder
[Cause]
The pickup position of the tape feeder does not match with the '-' marked position of
the tape guide.
[Measures]
Calibrate the position using the calibration jig provided by Hanwha Precision
Machinery Co., Ltd..
E0127 Deformed vertical position of the feeder
[Cause]
The position setting pin of the feeder base is worn or there are foreign materials in the
hole into which the position setting pin or the feeder base position setting pin is
inserted
[Measures]
When removing foreign materials or replacing the worn part, contact our designated
C/S company or local agent for proper measures. (Replace the position setting pin)
E0128 Incorrect part feeding position due to worn or deformed feeder parts
[Cause]
1) Distorted eccentric pin setting the position of the sprocket.
2) Parts of ratchet, stop pawl, etc. are worn out.
[Measures]
1) Calibrate the position using the calibration jig provided by Hanwha Precision
Machinery Co., Ltd..
2) ontact our designated C/S company or local agent for proper measures.
E0129 Incorrect part feeding position due to foreign materials on the sprocket, ratchet, etc.
[Cause]