1-17 System Messages of the MMI and Solutions  Foreign materials on the sprocket, ratchet, etc. [Measures]  Clean the sprocket, ratchet, etc. periodically . E0130 Incorrect setup of the part supply po sition according …

100%1 / 204
1-16
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
[Measures]
Remove the part or foreign materials.
E0125 The X part feeding position is incorrect due to a problem with the feeder
[Cause]
Incorrect X pickup position of the tape feeder
[Measures]
Adjust the X pickup position of the tape feeder using the calibration jig provided by
Hanwha Precision Machinery Co., Ltd..
E0126 Incorrect setup of the part feeding position of the feeder
[Cause]
The pickup position of the tape feeder does not match with the '-' marked position of
the tape guide.
[Measures]
Calibrate the position using the calibration jig provided by Hanwha Precision
Machinery Co., Ltd..
E0127 Deformed vertical position of the feeder
[Cause]
The position setting pin of the feeder base is worn or there are foreign materials in the
hole into which the position setting pin or the feeder base position setting pin is
inserted
[Measures]
When removing foreign materials or replacing the worn part, contact our designated
C/S company or local agent for proper measures. (Replace the position setting pin)
E0128 Incorrect part feeding position due to worn or deformed feeder parts
[Cause]
1) Distorted eccentric pin setting the position of the sprocket.
2) Parts of ratchet, stop pawl, etc. are worn out.
[Measures]
1) Calibrate the position using the calibration jig provided by Hanwha Precision
Machinery Co., Ltd..
2) ontact our designated C/S company or local agent for proper measures.
E0129 Incorrect part feeding position due to foreign materials on the sprocket, ratchet, etc.
[Cause]
1-17
System Messages of the MMI and Solutions
Foreign materials on the sprocket, ratchet, etc.
[Measures]
Clean the sprocket, ratchet, etc. periodically.
E0130 Incorrect setup of the part supply position according to tray shape and part
characteristics
[Cause]
1) Defective part pickup according to the tray for odd shaped parts
2) Limitation of the part pickup of the gripper according to the position of the odd shaped
tray part (center, edge)
[Measures]
1) Clean the sprocket, ratchet, etc. periodically.
2) Check the shape of the odd-shaped tray and gripper stroke and replace the gripper with
an appropriate one
E0131 Incorrect setup of Z and Pick Z values
[Cause]
1) The user entered an incorrect part thickness.
2) The user entered an incorrect Z value when entering the feeder pickup point.
3) For parts fed by the tray feeder, the Pick Z value is set incorrectly
[Measures]
1) Input the height of the part measure using vernier calipers.
2) In the case of the tape reel, the Z value is a positive (+) value. Usually, set the value so
that it becomes less than the usual part thickness by 0.1~0.2 mm. In the case of the
embossed reel, set a negative (-) Z value to -0.1.
3) Teach the Pickup Z value manually and input the correct value.
E0132 Foreign materials on the feeder base slot and clamp
[Cause]
There are foreign materials in the feeder base slot or clamp.
[Measures]
Remove foreign materials, if any, and clean the feeder base periodically.
E0133 Incorrect Z offset setup
[Cause]
The Z axis offset has been set up incorrectly
[Measures]
1-18
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
Correctly calibrate the Z axis offset again referring to the Administrator's Guide
manual.
E0134 When the Z offset is incorrect
[Cause]
The Z axis offset has been changed due to external causes including defects with the Z
axis motor.
[Measures]
Contact our designated C/S company or local agent for proper measures.
E0140 Standard nozzle is not used
[Cause]
A genuine nozzle is not used
[Measures]
Use the standard nozzle supplied by Hanwha Precision Machinery Co., Ltd.. The
'HANWHA' logo is printed on the side of the nozzle supplied by Hanwha Precision
Machinery Co., Ltd..
E0141 Damaged nozzle tip, abnormal nozzle spring tension
[Cause]
The nozzle spring does not move properly
[Measures]
Inject oil onto the nozzle spring referring to the Maintenance Handbook.
For further details, refer to the following documents:
Technical Reference : Refer to the Handbook.
E0142 The nozzle is clogged
[Cause]
The nozzle is clogged due to defective maintenance
[Measures]
Clean the nozzle periodically referring to the Maintenance Handbook.
E0143 The nozzle not suitable for the part used
[Cause]
Since the nozzle (gripper) suitable for the part is not used, the corresponding part is
not picked up (gripped) or is jammed in the nozzle.
[Measures]