1-27 System Messages of the MMI and Solutions Incorrect Part Placement Part Placement on Defective PCB The Z-axis motor driver has a problem E0422 Influence by vibration Influence by X-axis vibration E0430 Influence …

1-26
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
Part is placed abnormally - Abnormal placement error [Refer to Section21.2.2.2 ]
Placement Error
Detection of defective
part pickup failed
The vacuum sensor has a problem. E0150
Defective nozzle check sensor operation
(PIP part)
E0351
Defective side view camera recognition E0352
Defective PCB
sensor
E0360
Cause Description
Remark
s
Defective
placement
accuracy
Bent spindle E0400
Common data setup error E0401
Defective connection of Z-axis driving
system
E0402
The Z-axis motor driver has a problem E0403
The Z-axis LM guide is defective E0404
Distorted part
(placement offset
occurred)
.Calibration has not been performed for a
long period of time. Therefore, offset
occurred to the gantry
.Condition changed according to the site
environment
E0410
After a certain period of time, XY
coordinate distortion occurred in the gantry
working area.
E0411
X and Y limit setup error E0412
Front and rear fiducial camera offsets have
changed
E0413
Offset has changed by being pushed to the
Y-axis
E0414
camera offset has changed E0415
PCB jump E0416
Incorrect nozzle selection E0417
PartR application error E0419
Defective camera assembling E0420
Abnormal R axis driving system E0421
Cause Description
Remark
s

1-27
System Messages of the MMI and Solutions
Incorrect Part Placement
Part Placement on Defective PCB
The Z-axis motor driver has a problem E0422
Influence by
vibration
Influence by X-axis vibration E0430
Influence by Z-axis vibration E0431
Fiducial mark
recognition error
Defective fiducial camera outer illumination E0440
Defective fiducial outer illumination cable
contact
E0441
Impossible to search the fiducial mark
edge
(Fly camera reference mark and mirror are
contaminated)
E0442
Camera dip switch setup error E0443
Fiducial camera illumination setup error E0444
Damaged fiducial mark E0445
Fiducial mark was not used E0446
Placement
coordinate setup
error
Placement coordinate setup error E0450
Array coordinate setup error E0451
Cause Description Remarks
Part flip-over/standing
on edge
The algorithm for reverse insertion
and flip-over of the LED was not used
E0460
The reel is defective. E0461
The tape guide and tape shutter were
changed
E0462
The shutter does not operate properly E0463
Vision system
recognition error
Temporary recognition error of the
vision system
E0470
Cause Description Remarks
Bad mark recognition
error
.Bad mark size error
.Setup is performed so that the
fiducial mark will be recognized
after recognizing the bad mark first
E0480
Cause Description
Remark
s

1-28
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
1.2.2.1. Part Non-placement Error
E0300 Parts are blown because the vacuum pressure became low due to a defective
component of the head’s pneumatic system.Parts are blown because the vacuum
pressure became low due to a defective component of the head’s pneumatic system.
[Cause]
1) Defective solenoid valve
2) Defective Vacuum Pump (Applied only to the SM471, 481, DECAN F2
machine)
[Measures]
1) Perform solenoid valve operation test. If a problem occurs, contact or our local agent.
(Replace the solenoid valve.)
2) Check whether the vacuum level of the front vacuum gauge is -90kPa. If a problem
occurs, contact or our local agent. (Replace the Vacuum Pump.)
E0301 User parameter setup error (part thickness, illumination brightness, etc.)
[Cause]
1) Part transfer speed was set incorrectly
2) Part thickness was set incorrectly
3) The nozzle end does not come into contact with the upper surface of the PCB when the
spindle is moved down to the level at which the Z-axis height is '0' (zero)
[Measures]
1) Find and set the speed suitable for the corresponding part manually while changing
the part transfer speed little by little.
2) Lower the Z-axis to the placement height manually and set the height correctly.
3) Calibrate the Z-axis offset again referring to the Administrator's Guide.
E0302 Excessive fluctuation range of main pneumatic pressure (4.5 Mpa ~5.5 Mpa)
[Cause]
1) Incorrect setup of the main air regulator (0.45 Mpa ~0.55Mpa)
2) Large amount of moisture has entered the air pipes
3) Defective air compressor
[Measures]
1) Check whether the main air regulator gauge has any problems and replace it if
necessary. (Replace Air Regulator )
2) Check the air line. If it has too much moisture, clean it.
3) If the air compressor operates abnormally, replace it. Air Compressor