DECAN_S1_Troubleshooting_Guide(Eng_Ver1.3)_Print_Web.pdf - 第60页
1-36 Next Generation, Multi-Functional Plac er DECAN S1 Troubleshooting Guide E0420 The camera is assembled incorrectly. [Cause] Incorrect camera focus The camera illumination is turned on but the image taken by the …

1-35
System Messages of the MMI and Solutions
Perform the fiducial camera offset calibration referring to the Administrator's Guide.
E0414 The offset was changed since it was pushed to the Y-axis
[Cause]
The offset was changed since it was pushed to the Y-axis
[Measures]
Calibrate the placement accuracy using the mounter offset
E0415 The camera offset has been changed
[Cause]
The offset of the flying camera or fix camera occurred
[Measures]
Perform calibration of the head and camera referring to the Administrator's Guide.
E0416 The PCB jumps up while placing parts on it
[Cause]
1) Incorrect setup of the backup pin
2) Incorrect setup of the BUT Down speed
[Measures]
1) Check whether there is a clearance between the board and clamp plate in the Clamp
Up state and adjust the backup pin length.
2) Check the BUT lowering down time at the Conveyor Module Diagnosis and control
the speed control valve so that the lowering time may not exceed 150-170 ms.
E0417 A nozzle not suitable to the part was used
[Cause]
A nozzle not suitable to the part was used
[Measures]
Change the nozzle with the one suitable for the corresponding work referring to the
Operation Handbook.
E0419 Incorrect application of PartR
[Cause]
Incorrect placement angle
[Measures]
Apply the PartR suitable for the corresponding part.

1-36
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
E0420 The camera is assembled incorrectly.
[Cause]
Incorrect camera focus
The camera illumination is turned on but the image taken by the camera does not
appear
[Measures]
Contact our designated C/S company or local agent. (Replace the camera module)
E0421 The R-axis driving system was not connected properly
[Cause]
Defective motor or belt connection
[Measures]
Contact our designated C/S company or local agent. (Check the driving motor and belt
for any defect and reassemble them)
E0422 The Z-axis motor driver does not operate properly
[Cause]
Defective Z-axis motor driver.
[Measures]
Contact our designated C/S company or local agent. (Replace Z-axis motor driver.)
E0430 A placement error occurred due to X-axis vibration
[Cause]
Excessive X-axis vibration or noise
[Measures]
Apply grease to the X-axis and reassemble the X-axis ball screw.
E0431 A placement error occurred due to Z-axis vibration
[Cause]
Excessive Z-axis vibration or noise
[Measures]
Readjust the Z-axis tension.
E0440 Fiducial camera outer illumination is abnormal
[Cause]
The fiducial camera outer board is defective
[Measures]

1-37
System Messages of the MMI and Solutions
Check that the fiducial mark of the PCBs under production is defective first and that
the fiducial mark is set properly. Then check that the illumination for the fiducial mark
recognition is set properly. If the illumination board has a problem, contact our
designated C/S company or local agent. (Replace the outer illumination board of the
fiducial camera)
E0441 The fiducial outer illumination board cable is not connected properly
[Cause]
The fiducial outer camera illumination board cable is not connected properly
[Measures]
Secure the cable firmly and reassemble it. If the cable has a problem, contact our
designated C/S company or local agent. (Outer illumination board cable of the fiducial
camera)
E0442 Impossible to search the fiducial mark edge
[Cause]
1) The reference mark of the fly camera is contaminated
2) The folding mirror is contaminated
[Measures]
1) Clean the fly camera reference mark and folding mirror.
2) When recognizing the part, release the setup for the reference mark recognition.
(Change the constant: OPT_HRS_VISION: 1 → 0)
E0443 Camera dip switch setup error
[Cause]
Incorrect camera focus
The illumination is turned on, but the image from the camera does not appear
The camera is installed properly, but the image from the camera does not appear
[Measures]
Check the setup of the camera dip switch. (Internal synchronization, external
synchronization, shutter speed)
E0444 The fiducial camera illumination is not set properly
[Cause]
The brightness of the illumination is set too high or camera setup is not performed
properly
[Measures]