Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
[Measures]
Check the part pickup position of the feeder.
If it is picked up properly, check 'Ignore Center Offset' and perform setup to avoid an
occurrence of the corresponding error.
$aa0b The part angle deviates from the reference angle.
[Cause]
The inspected part angle (T) deviates from the reference angle by more than ±30°.
[Measures]
After checking the information of the registered part, check the pickup height.
$aa0f The part lead height is recognized to be smaller than that of the registered part.
[Cause]
The lead height of the inspected part is recognized to be smaller than the lead height of
the registered part.
[Measures]
Check the lead height information of the registered part. If necessary, adjust the
minimum allowable height value.
$aa10 The part lead height is recognized to be higher than that of the registered part.
[Cause]
The lead height of the inspected part is recognized to be higher than the lead height of
the registered part.
[Measures]
1-45
System Messages of the MMI and Solutions
Check the lead height information of the registered part. If necessary, adjust the
maximum allowable height value.
$aa11 Part area is too small.
[Cause]
The part size is smaller than the registered part size information.
[Measures]
After checking the size of the registered part, adjust the illumination so that the part
can be seen clearly.
$aa12 Part area is too large.
[Cause]
The part size is larger than the registered part size information.
[Measures]
After checking the size of the registered part, adjust the illumination so that the part
can be seen clearly.
$aa14 The part center deviates too much.
[Cause]
The center of the picked part deviates from the nozzle center too much.
[Measures]
Check the part pickup position. If necessary, change the reference center position.
$aa1b The X center of the part deviates too much.
1-46
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
[Cause]
The center of the picked part deviates from the nozzle center too much in the X
direction.
[Measures]
Check the part pickup position. If necessary, change the reference center position.
$aa1c The Y center of the part deviates too much.
[Cause]
The center of the picked part deviates from the nozzle center too much in the Y
direction.
[Measures]
Check the part pickup position. If necessary, change the reference center position.
$aa1d The part width is greater than the reference value.
[Cause]
The width of the picked part is measured to be greater than that of the registered part.
[Measures]
Check the registered part information. If necessary, check the illumination and adjust
the allowable value.
$aa1e The part width is less than the reference value.
[Cause]
The width of the picked part is measured to be less than that of the registered part.
[Measures]
Check the registered part information. If necessary, check the illumination and adjust
the allowable value.