1-73 System Messages of the MMI and Solutions  Make the width of all co nv eyor stations identical. $306a Timeout occurred while chan ging conveyor width. [EMER LEVEL] [Problem]  The conveyor width failed to be adjuste…

100%1 / 204
1-72
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
$3055 Attempt was made to turn the belt while already turning. [EMER LEVEL]
$3059 An error occurred to the rail axis controller. [EMER LEVEL]
[Problem]
A command that moves the conveyor was transmitted to the step control board, but an
error occurred.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.
Check the state of the corresponding step control board and driver.
$305b Exceeded the conveyor width movement range. [EMER LEVEL]
[Problem]
Attempt was made to adjust the conveyor width exceeding the maximum or minimum
width.
[Solution]
Perform setup of the width adjustment according to the specification of the current
machine..
$3060 Attempt was made to adjust the conveyor width while the conveyor width was already
being adjusted.. [EMER LEVEL]
$3061 The conveyor needs to be homed. [EMER LEVEL]
[Problem]
When operating the conveyor that was not homed.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.
Supply power to the motor of the machine by pressing the “READY” button.
Home all axes related to conveyor and perform operation related to conveyor.
$3067 Cannot begin production since the conveyor rail width does not match with the PCB
width. [EMER LEVEL]
[Problem]
There is difference between conveyor stations.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.
Supply power to the motor of the machine by pressing the “READY” button.
1-73
System Messages of the MMI and Solutions
Make the width of all conveyor stations identical.
$306a Timeout occurred while changing conveyor width. [EMER LEVEL]
[Problem]
The conveyor width failed to be adjusted as designated within designated time while
changing conveyor width.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.
Check if there is any mechanical interference while changing conveyor width.
Check the operation state of the step control board and PB driver related to the width
adjustment of the corresponding conveyor
$306b Timeout occurred while the conveyor is homed. [EMER LEVEL]
[Problem]
The conveyor width failed to be adjusted as designated within designated time while
homing the rail axis.
[Solution]
Take measures same as those against the error code "$306a”.
$306c An error occurred to the shuttle controller. [EMER LEVEL]
[Problem]
The machine operated incorrectly to the command related to the shuttle.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.
Check if there is mechanical interference related to the shuttle movement.
Check the operation state of the step control board and PB driver related to the shuttle
movement.
$306e The shuttle moved out of its movement range. [EMER LEVEL]
[Problem]
The shuttle moved out of its mechanical movement range..
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.
Supply power to the motor of the machine by pressing the “READY” button.
1-74
Next Generation, Multi-Functional Placer DECAN S1 Troubleshooting Guide
Check the range within which the shuttle can be moved and select the submenu for
calibration in the system setup menu and then click the <Axis Home Calibration>
button. Next select the corresponding shuttle axis and perform the home calibration
before restart.
$3073 Attempt was made to move the shuttle while the shuttle is being moved [EMER
LEVEL]
$3074 The shuttle needs to be homed. [EMER LEVEL]
[Problem]
When operating the shuttle that was not homed.
[Solution]
Take measures same as those against the error code “$3061”.
$3077 The shuttle movement was not completed. [EMER LEVEL]
[Problem]
Timeout occurred before the shuttle movement was completed.
[Solution]
Take measures same as those against the error code “$306c”.
$307b Timeout occurred when moving the shuttle. [EMER LEVEL]
[Problem]
Timeout occurred while moving the shuttle.
[Solution]
Take measures same as those against the error code “$306c”.
$307c Timeout occurred when moving the shuttle. [EMER LEVEL]
[Problem]
Timeout occurred while moving the shuttle.
[Solution]
Take measures same as those against the error code “$306c”.
$3080 There is an unknown board in the station. [EMER LEVEL]
[Problem]
There is a station in which the PCB with no transfer history was detected.
[Solution]
Turn off the Buzzer by pressing the “STOP” button.
Switch the machine to “IDLE” mode by pressing the “RESET” button.