Samsung SM-Series Pneumatic T ape Feeder Users' Manual 1-8 1.2.5. Applicable pitch according to emboss depth A vailable pitc h differs according to the emboss depth ‘A ’ (Figure 1-7) . For related details, please co…

100%1 / 89
Overview
1-7
1.2.3. Applicable components
Square chips, MELF, TR, SOP, PLCC, odd-type components
(For the SM 8mm Embossing Type Tape Feeder, the maximum length of T
2
is 3.5
mm. for B1, it is 4.5 mm.)
Figure 1-6. Embossed Carrier Tape (8/12mm)
1.2.4. Table for pitch setting
Table 1-3. Table for pitch setting
2mm 4mm 8mm 12mm 16mm 20mm 24mm 32mm 40mm
0402
- - - - - - - -
8mm 2P
- - - - - - - -
8mm 4P
-
- - - - - - -
12mm
-
- - - - -
16mm
- - - - -
24mm
-
- -
32mm
-
44mm
-
56mm
-
72mm
-
88mm
-
: transfers by 1 rotation of the feeder cylinder
: transfers by 2 rotation of the feeder cylinder
- : Irregular pitch and cannot be set
Samsung SM-Series Pneumatic Tape Feeder Users' Manual
1-8
1.2.5. Applicable pitch according to emboss depth
Available pitch differs according to the emboss depth ‘A (Figure 1-7). For related details,
please contact our sales department, CS company (STS) or local agent.
Figure 1-7. Emboss depth
1.2.6. Feeder Dimension and Number of Occupied Slots
Table 1-4. Feeder Dimension and Number of Occupied Slots
8mm 12mm 16mm 24mm 32mm 44mm 56mm 72mm 88mm
Width (mm) 14.7 27.5 29.5 40 51 59.4 68.5 84.5 100.5
Number of
Occupied Slots
1 2 2 3 4 4 5 6 7
A
Overview
1-9
1.3. Reference plane for Z-axis height of SM tape feeder
The reference plane for Z-axis height of the SM tape feeder is beneath (above the main
frame) the tape at the pickup position.
Consequently, height of Z-axis at the pickup position is diverse according to the thickness
of the transportation tape.
The Z value of the pickup point is applied in various ways according to the types of tape
feeders. In addition, it varies depending on the types of supplied tape. In the case of the
embossed tape, the height must be set lower than that of the paper tape.
For embossed tape, set the Z value of the pickup point properly referring to the
component tape standards.
Tape Guide
Tape
Frame
Reference
Surface
Z = 0
Paper Tape Embossed Tape
Z > 0
Z < 0
Ta
p
e Guide
Frame