JBC_PHXLE-K_manual.pdf - 第3页

3 Features and Connections Pedal Connect or Heating Are as Main Switch Fi xi ng br acket s for XL P CB S up po r t Heater Unit Zon e B Zon e A USB-B Connec tor RJ45 C on ne ctor to C on so l e RJ1 2 Conn ecto r to R ob o…

100%1 / 20
2
Console ........................... 1 unit
Ref. ACE-A
Packing List
The following items are included:
Thermocouple ............ 3 units
Ref. PH218
Kapton Tape .................. 1 unit
Ref. PH217
Manual ............................ 1 unit
Ref. 0026284
XL PCB Support ...................................... 1 unit
Ref. PHXL-SA
XL Preheater Unit .................................... 1 unit
RJ45 Cable .................... 1 unit
Ref. 0019914
Metallic Supports for PCB
Ref. PH201.................... 4 units
Ref. PH202.....................4 units
Ref. PH203.....................4 units
This manual corresponds to the following references:
PHXLE-1K A (120V )
PHXLE-2KA (230V)
PHXLE-9KA (100V)
3
Features and Connections
Pedal Connector
Heating Areas
Main Switch
Fixing brackets for
XL PCB Support
Heater Unit
Zone B
Zone A
USB-B Connector
RJ45 Connector
to Console
RJ12 Connector
to Robot
Thermocouple
Connectors x8
(Type K)
Console
2,8” Color
TFT Screen
Start / Stop
USB-B Connector
RJ45 Connector
to Preheater Unit
USB-A Connector
Foot for Vertical Set Up
Button for Foot
Folding and
Unfolding
Support
Slot Clamps
Adjusting System
for Changing Height
Clamp Knobs
Sliding
Guides
Allen Key
For Electrical
Power Supply
Connection
www.jbctools.com
4
Connection to Power Supply
Peak Current Cable Connection Wire Section
Single-phase Three-phase Single-phase Three-phase
230V 30 A 10 A 4mm
2
1 mm
2
100V/120V 60 A 20 A 10 mm
2
2,5mm
2
PHXLE-KA can be connected to single-phase or three-phase networks. A power supply cable is
required. Use the following table to determine the cable size and connection:
Connection to
Power Supply
RJ45 Cable
Ref. 0 019914