ACT - Accuracy Check Tool - 第155页
ACT with SSW 7xx / User Manual 07/2017 Edition 47 Figure 4-17: Position (track 7) of waffl e pack tray carrier on X table CAUTION Do not reach into t he machine during the placement and mea surement proce sses! ► Place t…

ACT with SSW 7xx / User Manual 07/2017 Edition
46
4.2 Measuring with the ACT at the Station
You have already specified the placement and measurement programs at the station as described
in section 4.1.
► Now set up the components on the station.
4.2.1 Setting Up Components on the Component Table
► Open the machine cover.
► Place the manual waffle pack tray carrier or the feeder onto the specified tracks of the relevant
location.
Example of the position of manual waffle pack tray carrier with glass components for a
SIPLACE X3
NOTICE
The waffle pack tray carrier on an X machine or SX machine with an X-table must be on
track 21 (Figure 4-16
). Therefore, the waffle pack tray occupies track 7 to 35
(Figure 4-17).
NOTICE
Before you undock an X-table with a set ACT tray you should remove the ACT tray or
push it back under the centering / comb bar. Otherwise, it may get stuck in the tape
removal channel and get damaged.
Key:
(1) Waffle pack tray (3) X-table
(2) X table holder (4) Track 21
Figure 4-16: Position (track 21) of waffle pack tray carrier on X table

ACT with SSW 7xx / User Manual 07/2017 Edition
47
Figure 4-17: Position (track 7) of waffle pack tray carrier on X table
CAUTION
Do not reach into the machine during the placement and measurement processes!
► Place the waffle pack tray with the glass components for the relevant head type (TH, P&P,
C&P6) on the corresponding manual waffle pack tray holder (table, Figure 2-4) and push it to
the rearmost stop as displayed in Figure 4-16).
WARNING
Risk of head crash!
The catch of the tray holder must snap into place into the hole, otherwise the tray and
holder could tip sideways and the placement head could collide with the tray.
The intervention guard described in the next chapter must then be fitted.

ACT with SSW 7xx / User Manual 07/2017 Edition
48
4.2.1.1 Intervention Guard
WARNING
To ensure operational safety, all feeder modules must be set up on all tracks. If
insufficient feeder modules are available, an intervention guard ("dummy feeder") must
be set up on unoccupied tracks.
For S tables: 1 track 00116961-xx
6-10 tracks 00116962-xx
11-20 track 00116963-xx
For X tables: 1 track 00141226-xx
If the ACT waffle pack tray is used, the cover plate of the magazine is to be combined
with part "03073250-01 ACT intervention guard, complete" using the knurled screw to
form a single unit (see Figure 4-19
) and is only permitted to be set up in the machine in
this form (Figure 4-20).
Figure 4-18: Component parts of the intervention guard