ACT with SSW 7xx / User Manual 07/2017 Edition 57 Figure 4-32: Selecting board ► Select the required board (1). The boa rd most recent ly specified is al ways at the top of the list. When you have sele cted a board, the …

100%1 / 220
ACT with SSW 7xx / User Manual 07/2017 Edition
56
Figure 4-30: Service Tools view
Change to the Service view (1).
Click the Accuracy Check button (2).
Figure 4-31: Preparing for the accuracy check
Now click the Prepare for accuracy check button (1).
The machine automatically switches to standalone mode.
ACT with SSW 7xx / User Manual 07/2017 Edition
57
Figure 4-32: Selecting board
Select the required board (1). The board most recently specified is always at the top of the list.
When you have selected a board, the corresponding setup appears at this point (2).
Confirm the selection of the board and click the Select as accuracy-check-board button (3).
Press the Start key before you insert the board (otherwise it will not be placed but immediately
be moved to the output section).
Push the board into the input section (see also section 4.2.2 and section 4.2.4.2).
The board gets placed and then the measurement starts automatically.
NOTICE
The machine should not be operated during the measurement!
A dialog box opens in which the current measurement operation is displayed.
The fiducials which are currently being measured will be displayed.
ACT with SSW 7xx / User Manual 07/2017 Edition
58
Example of measurement operation with the Cerampads ceramic components:
Figure 4-33: Example of measurement window with Cerampads
Example of measurement operation with glass components:
Figure 4-34: View of measurement window with glass components (pseudo color view)
Key:
(1) Fiducials on the ACT plate
(2) Fiducials on the glass component