ACT with SSW 7xx / User Manual 07/2017 Edition
68
4.2.7 Working with the ACT under Station Software 709.xx and Higher
NOTICE
It is not
necessary to install any additional software on the station computer on machines
running version 7.xx and higher of the station software.
Requirements:
● You have already sent a placement/measurement program to the station as described in
section 4.1.
● You have set up the station as described in section 4.2.1.
Figure: 4-44: Switching the user level
► Switch to the Einstellungen (Settings) view (1).
► Switch to Benutzereinstellungen (User settings) (2).
► Switch to the Service (Kunde) (Machine service) user level (3).
► Enter the service password.

ACT with SSW 7xx / User Manual 07/2017 Edition
69
Figure 4-45: Service Tools view
► Switch over to the Display maintenance related views view (1).
► Switch over to the Verify machine and subsystems view (2).
► Click the Machine verification button (3).
Figure 4-46: Preparing for the accuracy check
► Click the Prepare for machine verification button (1).
The machine automatically switches to standalone mode.

ACT with SSW 7xx / User Manual 07/2017 Edition
70
Figure 4-47: Selecting board
► Select the required board (1). The board most recently specified is always at the top of the list.
When you have selected a board, the corresponding setup appears at this point (2).
► Confirm the selection of the board and click the Select machine verification plate button (3).
► Press the Start key before you insert the board (otherwise it will not be placed but immediately
be moved to the output section).
► Push the board into the input section (see also section 4.2.2 and section 4.2.4.2).
The board gets placed and then the measurement starts automatically.
NOTICE
The machine should not be operated during the measurement!
A dialog box opens in which the current measurement operation is displayed.
The fiducials which are currently being measured will be displayed.