ACT with SSW 7xx / User Manual 07/2017 Edition 91 This results in t he following proced ure: 1. Vacuum tooling i s installed. 2. ACT measurement with offset co rrection for 20 µm on Lane 1 with Gantry 1 and 2 in Alternat…

100%1 / 220
ACT with SSW 7xx / User Manual 07/2017 Edition
90
6 ACT on SIPLACE TX micron Placement Machines
The SIPLACE TX micron series placement machines are divided into different accuracy classes:
TXmicron 20/25µm
TXmicron 15µm
While the machines in the 20/25 μm accuracy class can still be measured using ACT as described
above, a special toolkit must be used for the 15 μm class because of the high requirements.
Overview: Configurations of the TX micron machines
TX micron 20/25 µm
TX micron 15 µm
X-/Y-axes glass scale
X-/Y-axes glass scale
X-fiducial bar between conveyor and nozzle
changer
X-fiducial bar between conveyor and nozzle
changer
Calibration tools and calibration nozzles
required in nozzle changer
Calibration tools and calibration nozzles
required in nozzle changer
C&P20 M2 / CPP M
C&P20 M2
Vakuum tooling optional
Vakuum tooling - standard
Lifting table stabilizer for vacuum tooling
Y-fiducial bar at the vacuum tooling
Table 6-1: Differences between TX micron 20/25 µm and 15 µm
NOTICE
Placement Process
During the placement process, the X-fiducial bars are used for recalibration of the head
offset in both machine variants.
For this recalibration it is necessary that calibrating tools and one calibration nozzle in
the nozzle changer are available at both locations
The TX micron machine in accuracy class 15 μm / 3 S is specified for a board size up to 250 mm x
100 mm in I-Placement placement mode.
(I-Placement mode: Gantry 1 only places on Lane 1 and Gantry 2 only places on Lane 2).
If placement programs are placed in accuracy class 20/25 μm, the Alternating placement mode is
also permissible.
(Alternating mode: Gantry 1 and Gantry 2 can place on both conveyor lanes respectively).
For this reason, every TX micron machine in accuracy class 15 μm / 3 S must first be verified in
Alternating placement mode according to accuracy class 20 μm. (See also Table 4-5).
ACT with SSW 7xx / User Manual 07/2017 Edition
91
This results in the following procedure:
1. Vacuum tooling is installed.
2. ACT measurement with offset correction for 20 µm on Lane1 with Gantry 1 and 2 in
Alternating placement mode on "Micron ACT Plate 100 x 250 mm".
3. ACT measurement with offset correction for 20 µm on Lane2 with Gantry 1 and 2 in
Alternating placement mode on "Micron ACT Plate 100 x 250 mm".
4. Accepting the offset values of these measurements.
5. ACT measurement 15 µm on Lane 1 with Gantry 1 on "Micron ACT Plate 100 x 250 mm“
with vacuum tooling in I-Placement placement mode.
6. ACT measurement 5 µm on Lane 2 with Gantry 2 on "Micron ACT Plate 100 x 250 mm“
with vacuum tooling in I-Placement placement mode.
Working with ACT, see section 4.2.7 and section 4.2.8.
ACT with SSW 7xx / User Manual 07/2017 Edition
92
6.1 ACT at TX micron 15 µm
6.1.1 Requirements
Accuracy class 15 μm is only offered under certain conditions:
Vacuum tooling
Lifting table stabilizer
Y-fiducial bar
Only in the range of 250 x 100 mm
Only in I-Placement placement mode (Gantry 1 places on Lane 1, Gantry 2 places on Lane 2)
Therefore, these criteria must also be met for the measurements with the "Accuracy Test Device
ACT 15 μm".
The detection of accuracy 15 μm / 3 S can only be carried out with the toolkit described below.
Further prerequisites
"warm machine" => at least 2 h with position control
A complete calibration has been performed no longer than 3 months ago
Maintenance of heads and machine has been performed no longer than 3 months ago
Steps 1-4 of the automatic calibration have been performed currently.
Figure 6-1: Calibration steps