ACT with SSW 7xx / User Manual 07/2017 Edition
92
6.1 ACT at TX micron 15 µm
6.1.1 Requirements
Accuracy class 15 μm is only offered under certain conditions:
● Vacuum tooling
● Lifting table stabilizer
● Y-fiducial bar
● Only in the range of 250 x 100 mm
● Only in I-Placement placement mode (Gantry 1 places on Lane 1, Gantry 2 places on Lane 2)
Therefore, these criteria must also be met for the measurements with the "Accuracy Test Device
ACT 15 μm".
The detection of accuracy 15 μm / 3 S can only be carried out with the toolkit described below.
Further prerequisites
● "warm machine" => at least 2 h with position control
● A complete calibration has been performed no longer than 3 months ago
● Maintenance of heads and machine has been performed no longer than 3 months ago
● Steps 1-4 of the automatic calibration have been performed currently.
Figure 6-1: Calibration steps

ACT with SSW 7xx / User Manual 07/2017 Edition
93
6.1.2 Contents "Accuracy Test Device 15 µm" (Item No. 03159543-01)
Item description Item number Number
ACT package TX2i micron 15 03156157-01 1 x
ACT Test dummy 250 x 100 x 3 03156158-01 1 x
VacTool ACT SP1 cpl. 03156327-01 1 x
VacTool ACT SP2 cpl. 03156332-01 1 x
ACT Plate TX micron 03146927-01 1 x
Cover for ACT Plate TX micron 03156166-01 1 x
Ceram Pads 2x2mm on tapes 00359505-02 1 reel
Thermof. Revalpha
3195 V - 0,038 mm 230 x 95
03157505-01 50 x
Nozzle type 4204/6204 cpl. ceramic 03149000-xx 20 x
Nozzle magazine type 40xx 03101503-01 1 x
Nozzle 2204 cpl. cerami 03153518-xx 12 x
Nozzle magazine type 20xx 03066107-02 1 x
UM ACT withSSW 7xx 00198363-01 1 x
Case for ACT 1 x
Table 6-2: Contents of toolkit ACT 15 µm

ACT with SSW 7xx / User Manual 07/2017 Edition
94
6.1.3 Preparations for ACT 15 µm Measurement
The use of a vacuum tooling is one of the basic prerequisites of the ACT 15 μm measurement.
A complete vacuum tooling is available for each lane.
NOTICE
The vacuum toolings
are screwed together with the suction plate and measured together
with the plate.
The data is available on the enclosed USB stick. Uninstalling the suction plate or other
components is not permitted and would require a new calibration in Munich!
Figure 6-2: Vacuum tooling