Nordson_EFD_10th_Edition_Product_Catalog - 第93页
91 www.nordsonefd.com info@nordsonefd.com USA & Canada 800-556-3484 Europe 00800 7001 7001 Asia +86 (21) 3866 9006 Specications Progressive Cavity Pump Systems 7364076 ValveMate 7197PCP Controller Includes foot peda…

90
www.nordsonefd.com info@nordsonefd.com USA & Canada 800-556-3484 Europe 00800 7001 7001 Asia +86 (21) 3866 9006
Progressive Cavity Pump Systems
7365704 7197PCP-DIN-NX Controller
Includes breakout board and DB-15 cable. Motor
cable sold separately. Also features NX protocol
via Ethernet. For 2K applications, two
DIN controllers are required.
The network capable 7197PCP-DIN-NX controller provides precise control of
volumetric dispensing parameters for 797PCP and 797PCP-2K Series progressive
cavity pumps.
It allows direct communication with a Programmable Logic Controller (PLC) or other
manufacturing plant controllers using the NX protocol (network connectivity) via
Ethernet.
This technology enhancement allows operators to control all dispensing parameters
directly from a PLC or computer, giving the operator complete remote control of our
797PCP volumetric dispensing pumps.
7197PCP-DIN-NX
Controller
Features and Benets
• Ethernet control with NX protocol
• Communication between PLC and DIN controller
• Line, Volume, Weight, and Timed dispense modes for a wide range of
dispensing applications
• Nordson NX Client Application included, Windows-based graphical user
interface (GUI)
• Improve operational efciency by programming 797PCP pumps directly from a
central PLC
• Support Smart Factory integration using Ethernet compatibility with NX protocol
• Save time by updating multiple controllers simultaneously from a centralized
location
• Verify rotor movement with encoder count feedback
Cabinet size: 3.2w x 9.4h x 14.6d cm (1.27w x 3.70h x 5.75d")
Weight: 0.7 kg (1.5 lb)
Rotor speed: 10–150 RPM
Time range: 0.001–600,000 ms (1 s to 10 min)
Electrical power input: 24 VDC (±2%), 3.75 Amp maximum
Feedback circuits: Electronic switch, 24 VDC, 100 mA maximum
Cycle initiate: 24 VDC signal
Approvals: CE, TUV, RoHS, China RoHS, WEEE
Warranty: 1 year, limited
Specications
Download CAD Models:
www.nordsonefd.com/CAD
www.nordsonefd.com/7197PCP-DIN-NX

91
www.nordsonefd.com info@nordsonefd.com USA & Canada 800-556-3484 Europe 00800 7001 7001 Asia +86 (21) 3866 9006
Specications
Progressive Cavity Pump Systems
7364076 ValveMate 7197PCP Controller
Includes foot pedal. Order power cord separately.
Use with 797PCP Series pumps.
7364177 ValveMate 7197PCP-2K
Controller
Includes foot pedal. Order power cord separately.
Use with 797PCP-2K Series pumps.
7014871 American Plug Power Cord Kit
7014872 European Plug Power Cord Kit
The ValveMate 7197PCP Controller puts precise adjustment of volumetric dispensing
parameters at your ngertips with a high-resolution touchscreen interface. This provides
intuitive control of 797PCP Series progressive cavity pumps at factory workstations.
Advanced features, such as the ability to change the rotor speed when dispensing
a line around corners, deliver a high level of process control. Calibration functionality
makes dispensing results more accurate and repeatable after initial setup and setup
adjustments.
ValveMate 7197PCP
Controller
Features and Benets
• Intuitive touchscreen interface streamlines pump setup and programming at the
workstation
• Exact adjustment of dispensing parameters improves process control
Cabinet size: 21.2w x 10.8h x 17.3d cm (8.33w x 4.27h x 6.82d")
Weight: 1.8 kg (4.0 lb)
Rotor speed: 10–150 RPM
Time range: 0.001–600,000 ms (1 s to 10 min)
Electrical power input: 24 VDC (±2%), 3.75 Amp maximum
Feedback circuits: Electronic switch, 24 VDC, 100 mA maximum
Cycle initiate: Foot pedal
Approvals: CE, UKCA, TUV, RoHS, China RoHS, WEEE
Warranty: 1 year, limited
Download CAD Models:
www.nordsonefd.com/CAD

92
www.nordsonefd.com info@nordsonefd.com USA & Canada 800-556-3484 Europe 00800 7001 7001 Asia +86 (21) 3866 9006
92
Progressive Cavity Pump Accessories
797PCP-2K modular manifolds are engineered to provide mixing options for a broad
range of two-part uids and viscosities. The modular design allows use with or without
pressure sensors and is compatible with EFD bayonet and standard bell style mixers.
In addition, different ow path sizes allow optimization of uid ow for mix ratio
dispensing:
• For a 1:1 mix ratio, use the 2 x 2 mm bayonet manifold or 5 x 5 mm bell manifold.
• For a 4:1 or 10:1 mix ratio, use the 2 x 4 mm bayonet manifold or 2 x 5 mm bell
manifold.
With pressure sensors, manufacturers can
safeguard that two-component uids are
mixed properly. This ensures that two-
part uids cure correctly, saving valuable
production time and reducing rework
and rejects.
Pressure sensors monitor the pressure
of uid moving through Side A and Side
B of the 797PCP-2K modular manifolds,
allowing users to quickly identify an
increase or decrease in uid pressure that
could impact the mix ratio.
797PCP-2K Modular
Manifolds
Pressure Sensors
For use with:
1:1 Mix Ratio
Pressure Sensors (optional)
For use with:
797PCP-2K Modular Manifolds
For use with:
4:1 or 10:1 Mix Ratios
Pressure Sensors (optional)
7365963 797PCP-2K Manifold 2 x 2
Modular manifold with 2 mm x 2 mm flow paths.
Includes mixer retainer and screws for attaching
bayonet static mixers, plus two sensor port plugs
with O-rings if not using the pressure sensors.
7365985 797PCP-2K Manifold 5 x 5
Modular manifold with 5 mm x 5 mm flow paths.
Includes mixer retainer and screws for attaching
standard bell static mixers, plus two sensor
port plugs with O-rings if not using the pressure
sensors. Requires retaining nut #7702595 sold
separately.
7365999 Pressure Sensor Kit
Includes one pressure sensor with pressure sensor
cable that is 1.5 m (59") long and one signal
conditioner. Order two to monitor fluid pressure
of Part A and Part B fluids moving through the
797PCP-2K modular manifold.
7365965 797PCP-2K Manifold 2 x 4
Modular manifold with 2 mm x 4 mm flow paths.
Includes mixer retainer and screws for attaching
bayonet static mixers, plus two sensor port plugs
with O-rings if not using the pressure sensors.
7365983 797PCP-2K Manifold 2 x 5
Modular manifold with 2 mm x 5 mm flow paths.
Includes mixer retainer and screws for attaching
standard bell static mixers, plus two sensor
port plugs with O-rings if not using the pressure
sensors. Requires retaining nut #7702595 sold
separately.