91 www.nordsonefd.com info@nordsonefd.com USA & Canada 800-556-3484 Europe 00800 7001 7001 Asia +86 (21) 3866 9006 Specications Progressive Cavity Pump Systems 7364076 ValveMate 7197PCP Controller Includes foot peda…

100%1 / 148
90
www.nordsonefd.com info@nordsonefd.com USA & Canada 800-556-3484 Europe 00800 7001 7001 Asia +86 (21) 3866 9006
Progressive Cavity Pump Systems
7365704 7197PCP-DIN-NX Controller
Includes breakout board and DB-15 cable. Motor
cable sold separately. Also features NX protocol
via Ethernet. For 2K applications, two
DIN controllers are required.
The network capable 7197PCP-DIN-NX controller provides precise control of
volumetric dispensing parameters for 797PCP and 797PCP-2K Series progressive
cavity pumps.
It allows direct communication with a Programmable Logic Controller (PLC) or other
manufacturing plant controllers using the NX protocol (network connectivity) via
Ethernet.
This technology enhancement allows operators to control all dispensing parameters
directly from a PLC or computer, giving the operator complete remote control of our
797PCP volumetric dispensing pumps.
7197PCP-DIN-NX
Controller
Features and Benets
Ethernet control with NX protocol
Communication between PLC and DIN controller
Line, Volume, Weight, and Timed dispense modes for a wide range of
dispensing applications
Nordson NX Client Application included, Windows-based graphical user
interface (GUI)
Improve operational efciency by programming 797PCP pumps directly from a
central PLC
Support Smart Factory integration using Ethernet compatibility with NX protocol
Save time by updating multiple controllers simultaneously from a centralized
location
Verify rotor movement with encoder count feedback
Cabinet size: 3.2w x 9.4h x 14.6d cm (1.27w x 3.70h x 5.75d")
Weight: 0.7 kg (1.5 lb)
Rotor speed: 10–150 RPM
Time range: 0.001–600,000 ms (1 s to 10 min)
Electrical power input: 24 VDC (±2%), 3.75 Amp maximum
Feedback circuits: Electronic switch, 24 VDC, 100 mA maximum
Cycle initiate: 24 VDC signal
Approvals: CE, TUV, RoHS, China RoHS, WEEE
Warranty: 1 year, limited
Specications
Download CAD Models:
www.nordsonefd.com/CAD
www.nordsonefd.com/7197PCP-DIN-NX
91
www.nordsonefd.com info@nordsonefd.com USA & Canada 800-556-3484 Europe 00800 7001 7001 Asia +86 (21) 3866 9006
Specications
Progressive Cavity Pump Systems
7364076 ValveMate 7197PCP Controller
Includes foot pedal. Order power cord separately.
Use with 797PCP Series pumps.
7364177 ValveMate 7197PCP-2K
Controller
Includes foot pedal. Order power cord separately.
Use with 797PCP-2K Series pumps.
7014871 American Plug Power Cord Kit
7014872 European Plug Power Cord Kit
The ValveMate 7197PCP Controller puts precise adjustment of volumetric dispensing
parameters at your ngertips with a high-resolution touchscreen interface. This provides
intuitive control of 797PCP Series progressive cavity pumps at factory workstations.
Advanced features, such as the ability to change the rotor speed when dispensing
a line around corners, deliver a high level of process control. Calibration functionality
makes dispensing results more accurate and repeatable after initial setup and setup
adjustments.
ValveMate 7197PCP
Controller
Features and Benets
Intuitive touchscreen interface streamlines pump setup and programming at the
workstation
Exact adjustment of dispensing parameters improves process control
Cabinet size: 21.2w x 10.8h x 17.3d cm (8.33w x 4.27h x 6.82d")
Weight: 1.8 kg (4.0 lb)
Rotor speed: 10–150 RPM
Time range: 0.001–600,000 ms (1 s to 10 min)
Electrical power input: 24 VDC (±2%), 3.75 Amp maximum
Feedback circuits: Electronic switch, 24 VDC, 100 mA maximum
Cycle initiate: Foot pedal
Approvals: CE, UKCA, TUV, RoHS, China RoHS, WEEE
Warranty: 1 year, limited
Download CAD Models:
www.nordsonefd.com/CAD
92
www.nordsonefd.com info@nordsonefd.com USA & Canada 800-556-3484 Europe 00800 7001 7001 Asia +86 (21) 3866 9006
92
Progressive Cavity Pump Accessories
797PCP-2K modular manifolds are engineered to provide mixing options for a broad
range of two-part uids and viscosities. The modular design allows use with or without
pressure sensors and is compatible with EFD bayonet and standard bell style mixers.
In addition, different ow path sizes allow optimization of uid ow for mix ratio
dispensing:
For a 1:1 mix ratio, use the 2 x 2 mm bayonet manifold or 5 x 5 mm bell manifold.
For a 4:1 or 10:1 mix ratio, use the 2 x 4 mm bayonet manifold or 2 x 5 mm bell
manifold.
With pressure sensors, manufacturers can
safeguard that two-component uids are
mixed properly. This ensures that two-
part uids cure correctly, saving valuable
production time and reducing rework
and rejects.
Pressure sensors monitor the pressure
of uid moving through Side A and Side
B of the 797PCP-2K modular manifolds,
allowing users to quickly identify an
increase or decrease in uid pressure that
could impact the mix ratio.
797PCP-2K Modular
Manifolds
Pressure Sensors
For use with:
1:1 Mix Ratio
Pressure Sensors (optional)
For use with:
797PCP-2K Modular Manifolds
For use with:
4:1 or 10:1 Mix Ratios
Pressure Sensors (optional)
7365963 797PCP-2K Manifold 2 x 2
Modular manifold with 2 mm x 2 mm flow paths.
Includes mixer retainer and screws for attaching
bayonet static mixers, plus two sensor port plugs
with O-rings if not using the pressure sensors.
7365985 797PCP-2K Manifold 5 x 5
Modular manifold with 5 mm x 5 mm flow paths.
Includes mixer retainer and screws for attaching
standard bell static mixers, plus two sensor
port plugs with O-rings if not using the pressure
sensors. Requires retaining nut #7702595 sold
separately.
7365999 Pressure Sensor Kit
Includes one pressure sensor with pressure sensor
cable that is 1.5 m (59") long and one signal
conditioner. Order two to monitor fluid pressure
of Part A and Part B fluids moving through the
797PCP-2K modular manifold.
7365965 797PCP-2K Manifold 2 x 4
Modular manifold with 2 mm x 4 mm flow paths.
Includes mixer retainer and screws for attaching
bayonet static mixers, plus two sensor port plugs
with O-rings if not using the pressure sensors.
7365983 797PCP-2K Manifold 2 x 5
Modular manifold with 2 mm x 5 mm flow paths.
Includes mixer retainer and screws for attaching
standard bell static mixers, plus two sensor
port plugs with O-rings if not using the pressure
sensors. Requires retaining nut #7702595 sold
separately.