Autosite_Users_Manual - 第97页

Computer Remote Control AutoSite User Manual A-7 n 3C] S et data trans fer port > xxx.. .xxxx 3E] Select Keep Current file > 39] Delete all RAM files > 40] or n 40] Upload device inform ation See Applica tion No…

100%1 / 175
Computer Remote Control
A-6 AutoSite User Manual
Summary of Extended CRC Commands
Command Description Response
01] Display system configuration SSSS/AAAA/MM/PP/II/JJ>
nn
02] Set upload wait time >
n
03] Set device ID verify option HHHHHHHH> or
nn
04] Set Handler port baud rate >
xxx...xxxx
05] Set host command >
n
06] Select data bits >
n
07] Set next set member >
n
08] Select programmer mode >
xx
09] Set set size >
nn
22] Set data word width >
n
23] Select number of verify passes >
n
24] Select security fuse
programming option >
n
26] Specify logic verify options >
n
27] Set/clear enable/disable sec.
fuse >
n
28] Fill fuse map >
n
29] Set reject count option >
hhh
2A] or
hh
2A] Enable programming options >
hhh
2B] or
hh
2B] Disable programming options >
nhh
2C] Select memory fill option >
hh
2D] Vector test options
nn
2F] Return 8-character sumcheck HHHHHHHH>
xxx...xxxx
30] Set data file name >
n
31] Set data source/destination >
xxx...xxxx
33] Select device manufacturer >
xxx...xxxx
34] Select device part number >
xxx...xxxx
38] Load file from disk >
xxx...xxxx
3B] Delete disk file >
Computer Remote Control
AutoSite User Manual A-7
n
3C] Set data transfer port >
xxx...xxxx
3E] Select Keep Current file >
39] Delete all RAM files >
40] or
n
40] Upload device information See Application Note
n
41] Perform self-tests and report
results AAA...AA>
43] Upload yield tally See Application Note
46] Clear yield tally >
49] Suspend CRC mode Displays terminal screen
n
4A] Get filename from disk AAA...AA>
n
4D Select algorithms type >
n
4F Set RAM device selection >
n
52] Select algorithm media (floppy
disk or MSM) >
xxx...xxxx
53] Save RAM data to disk file >
54] Upload device footnote See Application Note
55] Upload device-specific message See Application Note
56] Upload memory verify failure
dd
PAAAAAAAAHH
hh
57] Returns checksum of last
operation >
58] Upload system ID HHHH HHHH HHHH>
n
59] Enable/disable capacitor
configuration test
0=enable; 1=disable
>
5A] Display list of parameters See Application Note
5B] Clear vector data >
5C] Load system files for CM
algorithm disk >
5D] Write system files to CM disk >
5E] Write algorithms to CM disk >
n
5F] Select CM algorithm drive for
creating CM algorithms >
60] Get number of sectors dd>
Command Description Response
Computer Remote Control
A-8 AutoSite User Manual
n
61] Get sector configuration settings HHHH HHHH>
nhhhhhhhh
62] Set sector configuration settings >
63] Reboot the programmer
xxx...xxxx
64] Select device part number for
CM (use
xxx...xxxx
33] to select
the manufacturer) >
A65] Return the software version
number
n
66] Set Abort on Empty Socket >
n
67] Set Checksum calculation word
size >
A7 Swap bytes >
DC] Device check See Application Note
EB] Input JEDEC data from host >
EC] Output JEDEC data to host >
FC] Restore CRC entry default
parameter >
FD] Restore user-defined CRC
parameters >
FE] Save user-defined CRC
parameters >
Command Description Response