00193889-0302_AI_LP-Ausrichtung_DE EN - 第43页

PCB alignment unit for SIPLACE S-27 HM / HS-60 / HF-series / X-series / D-series Edition 11/2006 41 : Calibrate the PCB refe rence cor ner . 2 Repeat this af ter di sassembling the option. 2 2 2.6 T roubleshooting HS-60 …

100%1 / 46
Stop washer
bottom
Wedge
Plain washer
Fixing belt
slat
path limiter
PCB alignment unit for SIPLACE S-27 HM / HS-60 / HF-series / X-series / D-series
Edition 11/2006
40
2
Fig. 2 - 14 Example HS-60
The stop washer ‘stopper PCB adjustment’ must
be threaded beneath the ‘path limiter slat’.
By moving the ‘stopper PCB adjustment’ must not
cover the ‘path limiter slat’!
2
Fig. 2 - 15 Example D1 /D2
PCB alignment unit for SIPLACE S-27 HM / HS-60 / HF-series / X-series / D-series
Edition 11/2006
41
: Calibrate the PCB reference corner.
2
Repeat this after disassembling the option. 2
2
2.6 Troubleshooting HS-60
Table down limit switch 2
The plain washers in the lifting table may cause the lifting t
able down limit switch to stop
responding. In this case do the following: 2
: Disassembly the lifting table.
: Mark the position of the inductive proximity sw
itch (if y
ou later wish to retract it).
: Now move the switch against moving direction until th
e switch responds (the LED lights up).
inductive
proximity switch
2
Fig. 2 - 1 Lifting table cylinder and limit switch
2
2
2
2
PCB alignment unit for SIPLACE S-27 HM / HS-60 / HF-series / X-series / D-series
Edition 11/2006
42