00196504-02_UM_X-Serie_SR70X_EN - 第174页
Technical data for the machine User manual SIPLACE X-series X feeder modules From software version SR.70x.xx 01/2011 EN edition 174 3.9.2 T echnical data for the SI PLACE X-series feeder modules The following p ages cont…

User manual SIPLACE X-series Technical data for the machine
From software version SR.70x.xx 01/2011 EN edition X feeder modules
173
3
Fig. 3.9 - 2 8 mm X tape feeder module - back view
(1) Entry to the tape guide channel with tape spring
(2) Flap on the cover foil container
(3) Integrated blade for cutting off the cover foil
(4) Removal handle, engaged
(5) Operator panel
(6) Drive motor for the cover foil packing device
(7) Drive motors for the tape conveyor
(8) Rotary valve for removing components
(9) Front slider guide
(10) Back slider guide
(11) Graphical representation of the pick-up position in relation to the component size

Technical data for the machine User manual SIPLACE X-series
X feeder modules From software version SR.70x.xx 01/2011 EN edition
174
3.9.2 Technical data for the SIPLACE X-series feeder modules
The following pages contain pictures of the X-series feeder modules and the technical data.
3.9.2.1 8 mm X tape feeder module
3
Fig. 3.9 - 3 8 mm X tape feeder module
3
8 mm X tape feeder module item no. 00141270-xx
8 mm X tape feeder module with splice sensor item no. 00141290-xx
Width 10.8 mm
Feeder module locations filled 1
Conveyor increment 1 mm / 2 mm / 4 mm / 8 mm
Changeover time for the component tape < 45 s
Changeover time for the preset feeder module
on the machine
≤ 8 s

User manual SIPLACE X-series Technical data for the machine
From software version SR.70x.xx 01/2011 EN edition X feeder modules
175
3.9.2.2 2x8 mm X tape feeder module
3
Fig. 3.9 - 4 2x8 mm X tape feeder module
3
2x8 mm X tape feeder module item no. 00141269-xx
2x8 mm X tape feeder module with splice sensor item no. 00141289-xx
Width 22.9 mm
Feeder module locations filled 2
Conveyor increment 1 mm / 2 mm / 4 mm / 8 mm
Changeover time for each component tape < 45 s
Changeover time for the preset feeder module
on the machine
≤ 8 s