00196504-02_UM_X-Serie_SR70X_EN - 第207页

User manual SIPLACE X-series Technical data for the machine From software version SR.70x.xx 01/2011 EN edition SIPLACE X-series component trolley 207 3.10.10 Used t ape channel on th e compo nent trolley docking unit In …

100%1 / 448
Technical data for the machine User manual SIPLACE X-series
SIPLACE X-series component trolley From software version SR.70x.xx 01/2011 EN edition
206
3.10.8.2 Maximum tape reel diameter in relation to the PCB conveyor height
3
PLEASE NOTE: 3
X-series component trolleys do not generally need quick-release axles. However, if the "Timeout"
error message occurs increasingly on the X feeder module, we recommend that you do use
quick-release axles.
3.10.9 Used tape chute
3
Fig. 3.10 - 10 Used tape chute for the component trolley docking unit
Depending on the PCB conveyor height, the length of the waste tape chute can be set so that the
pieces of tape are diverted directly into the waste tape container of the component trolley.
PLEASE NOTE 3
The used tape chute for the X-series can only be installed on the component trolley docking unit
for the X-series (see Fig. 5.15 - 3, page 346).
Without mount for the
additional tape reel
With mount for the
additional tape reel
PCB conveyor height
of the CO trolley
Tape reel diameter Tape reel diameter
without quick-release axle with quick-release axle
830 mm 17" 15" < 15"
900 mm 19" 17" 15"
930 mm 19" 19" 17"
950 mm 19" 19" 19"
User manual SIPLACE X-series Technical data for the machine
From software version SR.70x.xx 01/2011 EN edition SIPLACE X-series component trolley
207
3.10.10 Used tape channel on the component trolley docking unit
In the standard version, the used tape channel can guide component tapes with a maximum
pocket height of 12 mm to the pneumatic tape cutter.
3
Fig. 3.10 - 11 Used tape channel - CO trolley docking unit, SIPLACE X-series
(1) Inlet slot for the used tapes
(2) Outlet slot for the used tape above the pneumatic tape cutter
(3) Dividing plate for tapes < 12 mm (can be removed for tapes > 12 mm)
PLEASE NOTE
The separating plate (item 3 in Fig. 3.10 - 11
) can be removed for tape pockets higher than
12 mm (see Section 4.6
, page 287).
Do not position feeder modules with shallow pockets immediately beside feeder modules with
deep pockets. The used tapes could overlap and build up.
Technical data for the machine User manual SIPLACE X-series
SIPLACE X-series component trolley From software version SR.70x.xx 01/2011 EN edition
208