00196504-02_UM_X-Serie_SR70X_EN - 第236页

Setting up and commissioning User manual SIPLACE X-series Setting up the machine From software version SR.70x.xx 01/2011 EN edition 236 4.3.5 Fitting the extension ki t s to the machine frame 4.3.5.1 Fitting the extensio…

100%1 / 448
User manual SIPLACE X-series Setting up and commissioning
From software version SR.70x.xx 01/2011 EN edition Setting up the machine
235
Use the 19 mm bit to loosen the two hexagon socket head screws M24x90 (item 2 in Fig.
4.3 - 6
, page 234), and allow the outer machine foot (item 1 in Fig. 4.3 - 6, page 234) to slide
down slowly as far as the stop.
Insert the correct machine foot for the required PCB conveyor height.
There are two versions of the outer machine feet: 4
outer machine foot for the PCB conveyor height of 830 mm, length 369 mm,
item no. 03041008-01 (item 1 in Fig. 4.3 - 3
, page 231)
outer machine foot for the PCB conveyor heights of 900, 930 and 950 mm, length
439 mm, item no. 03000890-02 (item 2 in Fig. 4.3 - 3
, page 231)
Preset the height for each of the outer machine feet.
The distance between the underside of the machine foot and the bottom edge of the machine
frame should be as follows:
Use the size 36 fork wrench to turn the adjusting screw M24x2x120 (item 3 in Fig. 4.3 - 6
,
page 234
) until you obtain the distance values given in the above table for the particular trans-
port height.
Now use the fork-lift to carefully lower the machine until the machine feet touch the floor
evenly. There should always be a second person present to ensure that the machine remains
stable while it is being lowered. It may be necessary to loosen the outer machine feet clamps
slightly.
Continue carefully lowering the machine until the outer machine feet touch the screws
M24x2x120 (item 3 in Fig. 4.3 - 6
, page 234) for adjusting the height.
Make sure that the middle machine feet (see point 2 in Fig. 4.3 - 3
, page 231) do not yet touch
the floor. If necessary, screw the middle machine feet into the machine or spacer slightly.
PLEASE NOTE 4
A description of how to definitively adjust the machine can be found in Section 4.3.18
on page
279.
PCB conveyor height Distance from underside of machine foot
to bottom edge of machine frame
830 mm 120 mm
900 mm 190 mm
930 mm 220 mm
950 mm 240 mm
Setting up and commissioning User manual SIPLACE X-series
Setting up the machine From software version SR.70x.xx 01/2011 EN edition
236
4.3.5 Fitting the extension kits to the machine frame
4.3.5.1 Fitting the extension kit on the PCB output side
When the machine is delivered, the extension kit on the PCB output side and the PCB output -con-
nveyor are dismantled. The procedure for attaching the extension kit to the PCB output side is as
follows:
Fitting the output conveyor
see Section 4.3.6, page 237
Fitting the extension kit on the PCB output side see Section 4.3.7, page 238
Installing the axis unit see Section 4.3.8, page 244
Fitting the indicator lamp see Section 4.3.14, page 268
Integrating the machine into the line see Section 4.3.17, page 276
Making final adjustments to the machine see Section 4.3.18, page 279
4.3.5.2 Fitting the extension kit on the PCB input side
If the extension kit on the PCB input side was also removed for ease of transportation, you will
have to carry out the following steps before integrating the machine into the line (see Section
4.3.17
, page 276):
Fitting the input conveyor
see Section 4.3.9, page 252
Fitting the extension kit on the PCB input side see Section 4.3.10, page 254
Installing the box PC unit on the SIPLACE X4I see Section 4.3.12, page 263
Installing the axis unit see Section 4.3.13, page 266
Fitting the indicator lamp see Section 4.3.14, page 268
Integrating the machine into the line see Section 4.3.17, page 276
Making final adjustments to the machine see Section 4.3.18, page 279
User manual SIPLACE X-series Setting up and commissioning
From software version SR.70x.xx 01/2011 EN edition Setting up the machine
237
4.3.6 Fitting the output conveyor
4.3.6.1 Tools
Allen keys, DIN 911, set
Phillips screwdriver, size 1
4.3.6.2 Assembly
4
Fig. 4.3 - 7 Output conveyor - dual conveyor
(1) Rail, output conveyor
(2) Rail, processing conveyor 2
(3) Cable cover 20 x 200
(4) Countersunk screw, ISO 7046, M3x6, 2x per cable cover
(5) Cable cover 20 x 310
(6) Fillister head screw DIN 912, M3x5, 1x per cable cover
(7) Fillister head screw DIN 912, M6x16, and washer, 4x per rail
(8) Guide for hexagonal shaft
(9) Hexagonal shaft (single conveyor: one, dual conveyor: two)
(10) Drive unit