00196504-02_UM_X-Serie_SR70X_EN - 第25页
User manual SIPLACE X-series Introduction From software version SR.70x.xx 01/2011 EN edition Description of the machine 25 1.1.8 Serial number of the machine The serial number of the machine ca n be found in two differe …

Introduction User manual SIPLACE X-series
Description of the machine From software version SR.70x.xx 01/2011 EN edition
24
1
The 3D coplanarity sensor uses a laser line to scan the component leads or balls. When combined
with the SIPLACE TwinHead, this method returns faster measuring results for BGAs, for example.
1.1.7.3 Type 24 multicolor camera
From this software version onwards, the type 24 multicolor camera can be installed in place of the
standard PCB camera for measuring fiducials and ink spots. There is a choice of three illumination
modes to improve the contrast for fiducials or ink spots.
1.1.7.4 SIPLACE X4 LED placer
From software version SR.705 onwards we can supply a configuration for the SIPLACE X4 place-
ment machines that is specially tailored to the customer's needs when producing these LED back-
light units.
The SIPLACE X4 LED placer is based on a SIPLACE X4 placement machine with four C&P20 or
CPP placement heads. Special component tables are installed in place of CO trolleys. Special,
customer-specific bowl feeders supply the LED components. If only one bowl feeder is set up at
a location, there must be no tape cutter installed at this location. The feeder modules receive op-
timum support from the station software - with the empty feeder function, for example. Other
SIPLACE X feeder modules can also be set up. The single and dual conveyors process printed
circuit boards up to 850 mm long.
Placement machine Location
SIPLACE X2, SIPLACE X3 3
SIPLACE X4 2 or 3

User manual SIPLACE X-series Introduction
From software version SR.70x.xx 01/2011 EN edition Description of the machine
25
1.1.8 Serial number of the machine
The serial number of the machine can be found in two different places.
– The serial number, without leading zeros, e.g. B-1, is struck on the left-hand side of the ma-
chine frame, on the same side as the pneumatic unit (see item 1 in Fig. 1.1 - 2
).
– With leading zeros, e.g. B-001, the serial number is punched in the rating plate (see item 2 in
Fig. 1.1 - 2
).
1
Fig. 1.1 - 2 Places with the serial number on the X4 machine

Introduction User manual SIPLACE X-series
Description of the machine From software version SR.70x.xx 01/2011 EN edition
26
1.1.9 EU Declaration of Conformity
The product/device described below 1
Product: Placement machine
Type: SIPLACE X4I SIPLACE X4 SIPLACE X3 SIPLACE X2
Item no.: 0011977x 0011978x 0011975x 0011970x 1
manufactured by
ASM Assembly Systems GmbH & Co. KG
Rupert-Mayer-Str. 44
81379 Munich 1
conforms to the regulations and standards listed in the EU Declaration of
Conformity provided.
1.1.10 Use as prescribed
The product must only be used for its intended purposes as described in the catalogs and techni-
cal descriptions, namely the placement of SMD components, and only with the third-party equip-
ment and components recommended or permitted by ASM Assembly Systems GmbH & Co. KG
(ASM AS). Use for a different or extended purpose is not prescribed.
If the product is not used as prescribed, ASM Assembly Systems GmbH & Co. KG accepts no
liability for any damage that may occur and does not guarantee that the components will work
properly and without problems.
Use as prescribed also includes compliance with all the instructions in the user manual.
For the product to operate correctly and reliably, it must have been transported, stored, erected
and assembled correctly and must be operated and maintained with care.
1.1.11 Failure to use as prescribed
Failure to use the product as prescribed can result in both danger to life and limb and material
damage. For this reason, used other than as prescribed is expressly prohibited. If the product is
not used as prescribed, ASM Assembly Systems GmbH & Co. KG accepts no liability for any dam-
age that may occur and does not guarantee that the components will work properly and without
problems.
Use of the machine other than as prescribed includes, for example
– operation of the placement machine with safety equipment deactivated or removed.
– placement of components that do not meet the permitted specification.
– use of component feeder modules that have not been approved.
– use of unauthorized accessories and additional modules.