Setting up and commissioning User manual SIPLACE X-series Setting up the machine From software version SR.70x.xx 01/2011 EN edition 268 4 → Check the switch settings for S1 1: OFF 2: Not us ed 4.3.13.3 Fitting the X4I, X…

100%1 / 448
User manual SIPLACE X-series Setting up and commissioning
From software version SR.70x.xx 01/2011 EN edition Setting up the machine
267
4.3.13.2 Axis unit X4I, X4. X3 (gantry 1 and gantry 4) - Connecting the plugs
Connect the power cable as shown in the following diagram:
4
Axis unit, plugs Connecting cable Please note
Plug Cable
X41_1tq X41_1tq 03050919 Snap connector into place
X42_1tq X42_1tq 03050919 Snap connector into place
X45tq X45tq 03050920-W1 Snap connector into place
X46tq X46tq
03050920-W2
03050920-W3
Snap connector into place
X47tq X47tq
03050920-W4
03050920-W5
Snap connector into place
X01_3tq X4sr 03050881 Snap connector into place
X02_3tq X4st 03050882 Snap connector into place
X05_3tq X4vr 03050911 Snap connector into place
X06_3tq X4vt 03050912 Snap connector into place
X01_1tq X1so 03009771 Insert as far as the stop
X02_1tq X3so 03009772 Insert as far as the stop
X03_1tq X5so 03009773 Insert as far as the stop
X04_1tq X1sp 03009774 Insert as far as the stop
X05_1tq X1vo 03009831 Insert as far as the stop
X06_1tq X3vo 03009832 Insert as far as the stop
X07_1tq X5vo 03009833 Insert as far as the stop
X08_1tq X1vp 03009834 Insert as far as the stop
X09_1tq X3sp 03009775 Insert as far as the stop
X10_1tq X5sp 03009776 Insert as far as the stop
X11_1tq X3vp 03009835 Insert as far as the stop
X12_1tq X5vp 03009836 Insert as far as the stop
X03_3tq X03_3tq 03050883 Snap connector into place
X04_3tq X04_3tq 03050884 Snap connector into place
X07_3tq X07_3tq 03050913 Snap connector into place
X08_3tq X08_3tq 03050914 Snap connector into place
Setting up and commissioning User manual SIPLACE X-series
Setting up the machine From software version SR.70x.xx 01/2011 EN edition
268
4
Check the switch settings for S1
1: OFF
2: Not used
4.3.13.3 Fitting the X4I, X4, X3 axis unit (gantry 1 and gantry 4)
Carefully lift the axis unit onto the rail in the extension kit.
Make sure that you do not squash any cables.
Push the axis unit into the extension kit as far as the stop.
Secure the axis unit with the fillister head screw.
Insert the cover.
Fix the grounding cable to the doors (item 2 in Fig. 4.3 - 15
, page 254),
as shown in Fig. 4.3 - 16
on page 257.
Lock the doors.
4.3.13.4 Fitting the side plates
Fix the grounding cable to each side plate (item 6 in Fig. 4.3 - 15, page 254), as shown in Fig.
4.3 - 16
page 257.
Fix the side plate to the machine frame with 6 fillister head screws.
4.3.14 Fitting the indicator lamp
Connect the cables of the indicator lamps to the cables on the basic machine.
Insert the indicator lamp into the hole (item 2 in Fig. 4.3 - 22
, page 269) until the tube of the
indicator lamp projects sufficiently into the terminal beneath.
Tighten the hexagon socket head screw beneath the hole (item 3 in Fig. 4.3 - 22
, page 269).
X09_3tq X09_3tq 03050886 Snap connector into place
X10_3tq X10_3tq 03050885 Snap connector into place
X11_3tq X11_3tq 03050916 Snap connector into place
X12_3tq X12_3tq 03050915 Snap connector into place
X30_1tq
X30_2tq
X30_1tq
X30_2tq
03010051
03010051
Screw tightly
Axis unit, plugs Connecting cable Please note
Plug Cable
User manual SIPLACE X-series Setting up and commissioning
From software version SR.70x.xx 01/2011 EN edition Setting up the machine
269
4
Fig. 4.3 - 22 Fitting the indicator lamp
(1) Indicator lamps
(2) Hole for the indicator lamp
(3) Hole for the locking screw
4.3.15 Fixing the monitors
Fix the monitors and connect the cables.
Check the cable connections