00196504-02_UM_X-Serie_SR70X_EN - 第317页
User manual SIPLACE X-series Tasks on the machine From software version SR.70x.xx 01/2011 EN edition Indicato r lamp status displays 317 5.7.4 White indicator lamp s There is one white lamp on each sid e. Each lamp is c …

Tasks on the machine User manual SIPLACE X-series
Indicator lamp status displays From software version SR.70x.xx 01/2011 EN edition
316
5.7.3 Green indicator lamps
There is one green lamp on each side. They are connected in parallel so that they are always syn-
chronized. The green lamp signals that the machine is in production mode or has been paused.
PLEASE NOTE 5
A combination of green and white lamps is used during a reference run, a manual function or a
calibration process - see section 5.7.5, page 320.
Status Meaning
Off The machine was paused (by the operator or by an alarm)
Normal flashing The machine is running in production mode, but is not currently
producing for one or both of the following reasons:
– Waiting for PCB in the input area.
– And/or waiting for the output area to become free
("conveyor jam" or waiting for a PCB to be removed)
Brief flashing The machine was paused
and
The machine is currently unable to produce: something still has to
be done, such as:
– Waiting for job and set-up data
– A reference run - a part of it (such as feeder module position
detection, or checking the nozzle configuration) is still pend-
ing.
– The axes must be moved before production starts.
On The machine is producing, even though a warning was output.

User manual SIPLACE X-series Tasks on the machine
From software version SR.70x.xx 01/2011 EN edition Indicator lamp status displays
317
5.7.4 White indicator lamps
There is one white lamp on each side. Each lamp is controlled separately.
The white lamps signal
– that a warning
a
or alarm
b
was output (as specified in the operator FRS (Feature Require-
ments Specification) for the machine software).
– The type of warning or alarm.
– The location on the machine concerned.
5.7.4.1 Locations
a) The warning is a message to inform the operator about an error that will soon require the operator's in-
tervention. The operator can ignore the message for a certain time. After this time, the message will be
output as an alarm.
b) An alarm is a message that indicates that the machine was paused / stopped. Operator intervention is required
immediately.
Associated lamp Associated location
Left-hand lamp A module on the left-hand side of the conveyor, such as:
–Table
–MTC
– Feeder module
– Waffle-pack tray carrier
– Nozzle changer
– Gantry, if there are two gantries per placement area
– A head or part of the head (segment, nozzle, etc) if there
are two gantries per placement area
– A conveyor track in a dual conveyor configuration
– A PCB in a dual conveyor configuration (exception: prob-
lems with fiducials)
– An electronics card that is accessible on this side of the
machine.
In this case, the other lamps remain unchanged.
On a four-gantry machine, these are the sides numbered 3 and 4.
Right-hand lamp A module on the right-hand side of the conveyor, as for the left-
hand lamp.
On a four-gantry machine, these are the sides numbered 1 and 2.

Tasks on the machine User manual SIPLACE X-series
Indicator lamp status displays From software version SR.70x.xx 01/2011 EN edition
318
5.7.4.2 Basic principles
5
5.7.4.3 Priorities
5
If, at the same time,
– an alarm is signaled on the left or right, and
– a warning was not allocated to any side of the machine,
the warning will not be displayed as it has lower priority and both lamps are needed, but one is
already being used for the alarm.
The two lamps are
synchronized
A module with no reference to a specific side of the machine, such
as:
– General machine error that cannot be assigned to a spe-
cific side (example: the entire conveyor is no longer re-
sponding).
– Conveyor track in a single conveyor configuration.
– PCB in a single conveyor configuration.
– PCB fiducials in both single and dual conveyor configura-
tions.
– Gantry, if there is one gantry per placement area.
– A head or part of a head (segment, nozzle, etc) if there is
one gantry per placement area.
In this case, the lamps flash simultaneously as though they were
connected in parallel.
Associated lamp Associated location
Status Meaning
Off No warning and no alarm
Flashing Warning; the frequency varies according to the type of warning
On Alarm
Status Priority
Alarm is not allocated to a specific side of the machine. 1 - highest
Alarm is allocated to the left or right-hand side. 2 - high
Warning is not allocated to a specific side of the machine. 3 - low
Warning is allocated to the left or right-hand side. 4 - lowest