00196504-02_UM_X-Serie_SR70X_EN - 第368页
Station extensions User manual SIPLACE X-series Nozzle changer From softwar e version SR.70x.xx 01/2011 EN edition 368 6.1.2.5 Position of the nozzle changers for t he SIPLACE MultiSt ar on the X3 One or two nozzle chang…

User manual SIPLACE X-series Station extensions
From software version SR.70x.xx 01/2011 EN edition Nozzle changer
367
6.1.2.4 Position of the nozzle changers for the SIPLACE MultiStar on the X4
One or two nozzle changers may be installed at locations 1, 2, 3 and 4 for the CPP head (items 1
and 2 in Fig. 6.1 - 14
). This gives a total capacity of 8 nozzle changers.
In the standard configuration, the number of nozzle holders is:
40 magazines (20xx) = 480 nozzle holders
8 magazines (28xx) = 72 nozzle holders
6
Fig. 6.1 - 14 Position of the nozzle changers for the SIPLACE MultiStar on the X4 machine
(1) Nozzle changer, "row 1"
(2) Nozzle changer, "row 2"
(3) Reject bin for components
(4) Take-off device and reject bin for nozzles
(5) Nozzle magazine

Station extensions User manual SIPLACE X-series
Nozzle changer From software version SR.70x.xx 01/2011 EN edition
368
6.1.2.5 Position of the nozzle changers for the SIPLACE MultiStar on the X3
One or two nozzle changers may be installed at locations 1, 3 and 4 for the CPP head (items 1
and 2 in Fig. 6.1 - 15
). One nozzle changer may be installed at location 2. This gives a total ca-
pacity of 7 nozzle changers.
In the standard configuration, the number of nozzle holders is:
35 magazines (20xx) = 420 nozzle holders
7 magazines (28xx) = 63 nozzle holders
6
Fig. 6.1 - 15 Position of the nozzle changers for the SIPLACE MultiStar on the X3 machine
6
(1) Nozzle changer, "row 1"
(2) Nozzle changer, "row 2"
(3) Reject bin for components
(4) Take-off device and reject bin for nozzles
(5) Nozzle magazine

User manual SIPLACE X-series Station extensions
From software version SR.70x.xx 01/2011 EN edition Nozzle changer
369
6.1.2.6 Position of the nozzle changers for the SIPLACE MultiStar on the X2
1 or 2 nozzle changers may be installed at locations 1 and 3 for the CPP head (items 1 and 2 in
Fig. 6.1 - 16
). One nozzle changer may be installed at locations 2 and 4. This gives a total capacity
of 6 nozzle changers.
In the standard configuration, the number of nozzle holders is:
30 magazines (20xx) = 360 nozzle holders
6 magazines (28xx) = 54 nozzle holders
6
Fig. 6.1 - 16 Position of the nozzle changers for the SIPLACE MultiStar on the X2 machine
6
(1) Nozzle changer, "row 1"
(2) Nozzle changer, "row 2"
(3) Reject bin for components
(4) Take-off device and reject bin for nozzles
(5) Nozzle magazine