00197467-01_SM_DLM3-4_Kunde_en - 第35页

Service Work 3.8.3 Mechanical Adjustment (All Versions) Replacing the Valve P ositioning Drive for the Placemen t Circuit [00368075-xx] Service Manual SIPLACE Placement Heads DLM3/DLM4 35 ► Carefully turn the star to the…

100%1 / 88
Service Work
Replacing the Valve Positioning Drive for the Placement Circuit [00368075-xx] 3.8.3 Mechanical Adjustment (All Versions)
34 Service Manual SIPLACE Placement Heads DLM3/DLM4
3.8.3
3.8.3 Mechanical Adjustment (All Versions)
Mechanical Adjustment (All Versions)
Setting the valve positioning drive for the "placement position"
NOTICE
Adjustment valve plunger
The DLM1 (placement position) and all valve positioning drives of the DLM2, DLM3 and DLM4
heads can be set with the adjustment valve plungers.
Fit the dismantled head onto the head mount and
place both down on the front or place the head down
on a soft, ESD conductible surface on its front.
The lockscrew (1) and the fastening screw (2) of the
valve positioning drive need to be loosened or are
only screwed in slightly during assembly of the drive.
Instead of using a valve plunger, the adjustment
plunger is now inserted for the placement position
(P), as can be seen in the diagram.
Turn the adjustment valve plunger so that the tips of
the two centering pins are near to the cam disk be
-
hind the ball bearing. Use a pointed object to carefully
turn the cam disk so that it is in the "starting position"
(ball bearing horizontally aligned next to the drive
shaft).
Service Work
3.8.3 Mechanical Adjustment (All Versions) Replacing the Valve Positioning Drive for the Placement Circuit [00368075-xx]
Service Manual SIPLACE Placement Heads DLM3/DLM4 35
Carefully turn the star to the valve positioning drive so
that the two centering pins behind the ball bearing
grasp the fixtures on the cam disk.
The adjustment valve plunger swivels in the correct
position (centering pins parallel to cam disk).
Press the valve positioning drive in the direction of
the placement star and fasten the drive holder with
the 2.5 mm Allen key.
Now tighten the locking threaded pin with an Allen
key of size 0.89 mm. Press the valve positioning drive
against it. Do not tighten excessively as this could
push the valve positioning drive "backwards".
Remove the adjustment plunger by turning the place
-
ment star back and then rotating the adjustment
plunger out of the valve housing.
Service Work
Replacing the Valve Positioning Drive for the Reject Circuit [00367768-xx] (up to DLM3) 3.8.3 Mechanical Adjustment (All Versions)
36 Service Manual SIPLACE Placement Heads DLM3/DLM4
3.9
3.9 Replacing the Valve Positioning Drive for the Reject Circuit [00367768-xx] (up to DLM3)
Replacing the Valve Positioning Drive for the Reject Circuit
[00367768-xx] (up to DLM3)
Parts, equipment and tools
Used up to version 2: distance gauge 0.2 mm [00325445-xx]
Adjustment valve plunger for placement circuit [03068816-xx]
Available from version 3, applicable for all versions.
Preparation
Remove the head from the machine. For details about removing and fitting the placement head, refer
to the service manual for your machine.
Removal
NOTICE
Valve positioning drive, reject circuit , only up to DLM3
From version DLM4, there is no valve positioning drive for the reject circuit.
C&P6/12 adjustment valve plunger
1. Adjustment valve plunger for reject circuit C&P12
[03064290-xx]
2. Adjustment valve plunger for placement circuit
C&P12 [03068816-xx]
3. Adjustment valve plunger for reject circuit C&P6
[03068854-xx]
4. Adjustment valve plunger for placement circuit C&P6
[03065628-xx]
The labeling on the plungers has the following meaning:
6 = C&P6
12 = C&P12
P = placement circuit
R = reject circuit
1. Valve positioning drive for the placement circuit
[00368075-xx]
2. Valve positioning drive for the reject circuit
[00367768-xx]
3. Flat ribbon cable clamp
4. Flat ribbon cable clamp
Loosen the two Phillips screws on the flat ribbon ca
-
ble clamp (3) and (4).