00197467-01_SM_DLM3-4_Kunde_en - 第41页

Service Work 3.9.3 Mechanical Adjustment (From Version 03) Replacing the Valv e Positioning Drive for the Reject Circuit [00367768-xx] (up to Service Manual SIPLACE Placement Heads DLM3/DLM4 41 ► Use a pointed object to …

100%1 / 88
Service Work
Replacing the Valve Positioning Drive for the Reject Circuit [00367768-xx] (up to DLM3) 3.9.3 Mechanical Adjustment (From Version 03)
40 Service Manual SIPLACE Placement Heads DLM3/DLM4
3.9.3
3.9.3 Mechanical Adjustment (From Version 03)
Mechanical Adjustment (From Version 03)
Setting the valve positioning drive for the "reject position"
NOTICE
Adjustment valve plunger
The valve positioning drives of the DLM2 and DLM3 head reject position can be set with the
adjustment valve plungers.
CAUTION
Position must be correct
Even if your placement machine does not use the valve positioning drive for rejecting compo
-
nents (rejection vertically down), the position of this drive must still be correct. If this is not the
case, an incorrectly set valve positioning drive could have a negative influence on the plunger
positions during the reference run and during star rotation.
Fit the dismantled head onto the head mount and
place both down on the front or place the head down
on a soft, ESD conductible surface on its front.
The lockscrew (at the bottom side of the placement
head) and the fastening screw of the valve position
-
ing drive need to be loosened or are only screwed in
slightly during assembly of the drive.
Fit the adjustment valve plunger (1) in place of the
valve plunger, for the reject position (R) - as shown in
the diagram.
Turn the adjustment valve plunger so that the tips of
the two centering pins are near to the cam disk be
-
hind the ball bearing.
Service Work
3.9.3 Mechanical Adjustment (From Version 03) Replacing the Valve Positioning Drive for the Reject Circuit [00367768-xx] (up to
Service Manual SIPLACE Placement Heads DLM3/DLM4 41
Use a pointed object to carefully turn the cam disk so
that it is in the "starting position" (ball bearing horizon
-
tally aligned next to the drive shaft).
Carefully turn the placement star in the direction of
the valve positioning drive so that the two centering
pins behind the ball bearing grasp the fixtures on the
cam disk. The adjustment valve plunger (1) swivels
into the correct position (centering pins parallel to
cam disk).
NOTICE!
As the cam disk of the reject valve positioning drive is be
-
hind the connection board, this setting is slightly more
complex than that for the placement circuit.
Press the valve positioning drive in the direction of
the placement star and fasten the drive holder with a
2.5 mm Allen key.
Now tighten the locking threaded pin with an Allen
key of size 0.89 mm. Press the valve positioning drive
against it. Do not tighten excessively as this could
push the valve positioning drive "backwards".
Remove the adjustment plunger by turning the place
-
ment star back and then rotating the adjustment
plunger out of the valve housing.
Then replace the adjustment plunger with a plunger
and protection ring.
Service Work
Replacing the Light Barrier "Z Axis Up" [03053294-xx] 3.9.3 Mechanical Adjustment (From Version 03)
42 Service Manual SIPLACE Placement Heads DLM3/DLM4
3.10
3.10 Replacing the Light Barrier "Z Axis Up" [03053294-xx]
Replacing the Light Barrier "Z Axis Up" [03053294-xx]
Parts, equipment and tools
Light barrier, Z axis up DLM1/2/3 [03053294-xx]
Overview
Preparation
Remove the head from the machine. For details about removing and fitting the placement head, refer
to the service manual for your machine.
Removal
Switch off the machine and secure it to prevent unauthorized reactivation.
Remove the plug from the slot on the intermediate distributor.
Undo the two hexagon socket-head screw (1) and remove the flat ribbon cable clamp.
Loosen the two slotted screws (2).
Remove the light barrier "Z axis up" (3) with its cable.
Use the two slotted screws (2) to fix the "Z axis up" light barrier board (3). Move the board as far
upwards as the screws will tolerate.
Connect the ribbon cable plug to the slot on the intermediate distributor.
Use the flat ribbon cable clamp and the two hexagon socket-head screws (1) to fix the flat ribbon
cables.
Further installation is performed by following the above instructions in the reverse order.
1. 2 x M2.0x4 hexagon socket-head screws
2. 2 x slotted screws
3. Light barrier board "Z axis up"
1
3
2
CAUTION
Check how the cables are run!
Make sure that the flat ribbon cable is not pinched in the guide channel. Make sure that you
push the folded part of the flat ribbon cable for the "Z axis up" light barrier back under the
illumination board.
Note: a new version is available with a shortened flat ribbon cable.