Measuring Equipment and Tools
Calibration Tools for Vision Systems
64 Service Manual SIPLACE Placement Heads DLM3/DLM4
4.4
4.4 Calibration Tools for Vision Systems
Calibration Tools for Vision Systems
4.5
4.5 Z End Stopper Star Gauge for C&P6/12 [03019865-xx]
Z End Stopper Star Gauge for C&P6/12 [03019865-xx]
4.6
4.6 Power Pack for Star Installation
Power Pack for Star Installation
Use:
▪ C&P6/12head on the D, X and HF series:
Calibration tool [03010565-xx]
▪ C&P20 head on the X-Series (for component camera
type 23):
Calibration tool [03034148-xx]
▪ Machines with 4xx software:
Calibration tool [00316308-xx] (version II, transpar
-
ent)
Use:
The gauge is used to set the end stop position of the C&P
head Z axis.
Use:
The power pack is used as an adjustment aid for installa
-
tion of the star on C&P6/12 heads.

Measuring Equipment and Tools
Adjustment Aid for C&P DLM [00327005-xx]
Service Manual SIPLACE Placement Heads DLM3/DLM4 65
4.7
4.7 Adjustment Aid for C&P DLM [00327005-xx]
Adjustment Aid for C&P DLM [00327005-xx]
4.8
4.8 Belt Tensioning Device for Turning Station DLM [03063649-xx]
Belt Tensioning Device for Turning Station DLM [03063649-xx]
4.9
4.9 Belt Tension Measuring Device (00326015-xx)
Belt Tension Measuring Device (00326015-xx)
Complete set [00327005-xx]
Includes:
1. Gauge for star [00326164-xx]
2. Test probe 1.4 mm [00326160-xx]
3. Test probe 1.5 mm [00326161-xx]
4. Test probe 1.6 mm [00326162-xx]
5. Test probe 1.0 mm [00376656-xx]
6. Distance gauge [00325445-xx]
Measurement tools Application type
Gauge for star Setting the zero point correction for the star
Test probe 1.4 mm Setting the distance between the DP station incremental encoder and the glass
for the sleeve
Test probe 1.5 mm
Test probe 1.6 mm
Test probe 1.0 mm Setting the distance from the Z axis light barrier down to the sleeve shaft
Distance gauge Setting the distance of the valve plunger to the star
Use:
This device is used for setting the tension of the toothed
belt at the turning station.
This part is available from introduction of the turning sta
-
tion DLM from version 06 [00341780-06].
Use:
The belt tension measuring device is used to measure
the belt tensions (toothed belt) at the machine.

Measuring Equipment and Tools
Adjustment Valve Plunger for DLM Heads
66 Service Manual SIPLACE Placement Heads DLM3/DLM4
4.10
4.10 Adjustment Valve Plunger for DLM Heads
Adjustment Valve Plunger for DLM Heads
4.11
4.11 Antistatic Tweezers
Antistatic Tweezers
4.12
4.12 Universal Placement Head Mounting Rack [03056231-xx]
Universal Placement Head Mounting Rack [03056231-xx]
Adjustment valve plunger DLM head
Available from positioning unit version 3
Use the 0.2 mm setting gauge with DLM1.
1. Adjustment valve plunger for reject circuit C&P12
[03064290-xx] (DLM2, DLM3)
2. Adjustment valve plunger for placement circuit
C&P12 [03068816-xx] (DLM2, DLM3, DLM4)
3. Adjustment valve plunger for reject circuit C&P6
[03068854
-
xx] (DLM2, DLM3)
The C&P6 is not used in the DX series.
4. Adjustment valve plunger for placement circuit C&P6
[03065628
-
xx] (DLM2, DLM3)
The C&P6 is not used in the DX series.
The labeling on the plungers has the following meaning:
▪ 6 = DLM head with 6 segments
▪ 12 = DLM head with 12 segments
▪ P = placement circuit
▪ R = reject circuit
1. Antistatic tweezers, type Bernstein 5
-
192
[00377393
-
xx]
2. Antistatic tweezers, type Bernstein 5
-
195
[00377394
-
xx]
Use:
The universal placement head mounting rack is suitable
for TwinHead, C&P20, CPP, IC and DLM heads.