Montageanleitung Option Durchtransport SIPLACE HF-Serie / X-Serie / D3 Ausgabe 04/2010 18 1.5.3 X4i alle Seriennummern, die mit E beginnen (z.B. E-01) 1 Abb. 1.5 - 3 Hauptverteiler (Art.Nr.: 03059489-xx) 1 1

100%1 / 34
Montageanleitung Option Durchtransport SIPLACE HF-Serie / X-Serie / D3
Ausgabe 04/2010
17
1.5.2 X-Serie ab Seriennummer B-326
X4i alle Seriennummern, die mit D beginnen (z.B. D-01)
D3
1
Abb. 1.5 - 2 Hauptverteiler (Art.Nr.: 03046225-xx)
Montageanleitung Option Durchtransport SIPLACE HF-Serie / X-Serie / D3
Ausgabe 04/2010
18
1.5.3 X4i alle Seriennummern, die mit E beginnen (z.B. E-01)
1
Abb. 1.5 - 3 Hauptverteiler (Art.Nr.: 03059489-xx)
1
1
Assembly instructions Pass-through transport for SIPLACE HF-series / X-series / D3
04/2010 Edition
19
2 Assembly instructions
Pass-through transport option for
SIPLACE HF-series / X-series / D3
2.1 Note about the option
2
The Pass-through transport option is only intended to be activated in an emergency.
Its only purpose is to ensure that the placement machine's PCB convey
or can still be used even
though the station software is no longer running. This will allow the placement machine to be used
as a conveyor belt. 2
This function MUST be deactivated when carrying out repairs on the placement machine. To de-
activate the function, switch the placement machine off at th
e main power switch, otherwise the
axes might start up unexpectedly. The safety circuit is fully active while this option is switched on,
however. 2
Before you activate the option, push all the ga
ntries manually out of the conveyor area, making
sure that the Z-axes are in the top position and cannot be damaged. 2
2.1.1 Functional Description
After the main switch has been switched on, none of the three LEDs on the PCC (protective con-
tactor combination) lights. 2
If the button on the emergency conveyor is pressed, the first LED on the PCC lights (software re-
lease). The relais with the self-holding contact(24V) switch
es and is permanently held by means
of a self-holding contact. 2
The voltage for the conveyor belts, the tape cutter and the interm
ediate circuit voltage of the axis
systems is not present. The voltages are not switched until the safety circuit is closed and the start
button has been pressed (L2 and L3 of PCC light). If the safety circuit is interrupted, e. g. by an
emergency-off button or by opening a cover, the voltage of the PCC drops. As a result, the voltage
for the conveyor belts, the tape cutter and the intermediate ciruit voltage drops as well. 2
Testing the function: 2
If the safety circuit is closed and the start button is pressed, the PCB in the output conveyor of the
preceding
station is requested by the test machine, transported through the machine and passed
on to the subsequent station. 2