00196439-0202_MA_Option_Durchtransport_HF-Serie_X-Serie_D3 - 第21页
Assembly instructions Pass-through transpor t for SIPLACE HF-series / X-series / D3 04/2010 Edition 21 2.3 Safety instructions WA R N I N G The safety instructions from th e “Operational safety” cha pter of the user manu…
Assembly instructions Pass-through transport for SIPLACE HF-series / X-series / D3
04/2010 Edition
20
2.2 Required parts
2.2.1 Retrofit kit Option Pass-through transport SIPLACE / X-series / D3
(00119707)
2.2.2 Tools and consumables required
– Set of hexagon socket spanners
–Side cutters
– Wire stripper
– Power drill
– Drill bit 6,5 mm
2

Assembly instructions Pass-through transport for SIPLACE HF-series / X-series / D3
04/2010 Edition
21
2.3 Safety instructions
WARNING
The safety instructions from the “Operational safety” cha
pter of the user manual and servicing in-
structions take precedence over these instructions. 2
The SIPLACE placement machines are supplied with main power voltage.
Consequently parts of these systems carry dangerous voltages! Th
is voltage is present at certain
modules inside the machine base, even when the machine is switched off at the main power
switch.
Incorrect handling of the placement machine or touching live parts of the machine can result in
death or se
vere injury, and considerable damage to equipment.
BEFORE starting any work, shut down the operating system correctly,
then switch the machine
OFF at the main power switch and disconnect from the main power supply. In addition, the com-
pressed air supply must be switched off at the compressed air unit's main valve in the machine
base and
vented by actuating the needle valve on the compressed air unit.
There is DANGER for heart pacemaker wearers in the vicinity of the linea
r motors, as described
in detail in the "Special safety instructions for working in the vicinity of strong magnetic fields"
section of the user manual and service manual.
Always follow the accident prevention regulations, DIN or other sta
ndards and special safety
rules applicable in your country.
Pay attention to the information concerning residual voltages in
the Operational Safety chapter.
Follow the ESD regulations as described in the operationa
l safety section of the operating
instructions.
During the retrofit, always secure the machine to prevent access by other people and to prevent
it being switched on ag
ain. The procedure is described in the “Locking the machine…” section of
the user manual.
Working with the SITEST program further increases the risk of accident.
The SITEST program must only be used by authorized an
d trained personnel.
2
2
2.3.1 Definitions
2
Please note 2
2
2
2
Caution 2

Assembly instructions Pass-through transport for SIPLACE HF-series / X-series / D3
04/2010 Edition
22
2.4 Assembly
: Dock out the component trolley from the placement machine.
: Switch the placement machine off at the main switch.
2
: Remove the covers shown in the photograph.
Remove the covers
2
2
2
2
2