00194553-01 - 第20页

Retrofit instructions - Schmersal switch door interlock for the SIPLACE MTC 2 07/2005 Edition 20 2.5 Function test : T est whether – the safety circuit is closed when the sa fety doors are closed, – the safety circuit is…

100%1 / 22
Retrofit instructions - Schmersal switch door interlock for the SIPLACE MTC 2
07/2005 Edition
19
: Unscrew the two screws on the side switch.
2
2
: Follow the procedure described for the switch on the front for the switch on the side.
Pull the switch out and unscrew it from the mounting plate (2 screws).
Remove the switch from its mount (2 screws).
Reverse the order described above to fit the new switch.
2
: Replace the actuator.
: Adjust the switch and actuator with respect to one another.
2
: Fit the right-hand cover and the two front protective covers.
2
Connect the MTC 2 to the main power supply. 2
: Switch the MTC2 on at the main switch.
2
Two screws
Side switch
Retrofit instructions - Schmersal switch door interlock for the SIPLACE MTC 2
07/2005 Edition
20
2.5 Function test
: Test whether
the safety circuit is closed when the safety doors are closed,
the safety circuit is interrupted when the safety door is opened.
2