8 New functionality in 504.01 SIPLACE Software Guide SR.504.xx 8.7 SITEST – new functions Issue 01/03 EN 90 – MTC - Functions: – Both l ifting axes can be move d to the se rvice position . – Both fe ed axe s can be moved…

100%1 / 106
SIPLACE Software Guide SR.504.xx 8 New functionality in 504.01
Issue 01/03 EN 8.7 SITEST – new functions
89
Twin Head 8
8
Calibrating heads and cameras: The dialog box "All heads and cameras" allows you to select
the calibration functions for each processing area.
Heads and mapping: The "Heads and mapping" dialog box can now be used to select the
mapping width for the new or old mapping plate (Abschnitt 8.7.1).
Conveyor edges. The correction values for the width adjustment of the conveyor are
determined.
Teaching the gantry: Move to machine positions with the PCB camera.
Gantry continuous run: A continuous run is carried out with the X and Y axes simultaneously.
Gantry - Axis functions: The travel range is determined automatically for the selected axis; the
limit switch positions as well as the minimum and maximum travel range are then displayed
and transferred to the axis.
Teach RV head: Move to machine positions with the sleeve of the RV head.
RV head - RV head and camera: The head offset is calibrated (offset between PCB and RV
camera).
Calibrate RV camera: The RV camera is calibrated.
Twin Head:
Functions for supporting the Twin Head
Axis functions for supporting the Twin Head
Head board for supporting the Twin Head
IC camera, FC camera
–Calibration
TH mapping
Nozzle changer head functions, magazine functions
Conveyor width
Conveyor – Functions
Component camera 1 8 Component camera 2 8 Nozzle changer 8
IC camera (type 7) FOV
38 x 38 3 levels 8
FC camera (type 11) FOV
9.2 x 11.4 8
Twin Head 3 / 1 8
IC camera (type 10) FOV
38 x 38 4 levels 8
FC camera (type 20) FOV
11 x 11 8
Twin Head 5 / 2 8
IC camera (type 22) FOV
45 x 60 8
FC camera (type 21) FOV
21 x 21 8
Twin Head 8 / 4 8
8 New functionality in 504.01 SIPLACE Software Guide SR.504.xx
8.7 SITEST – new functions Issue 01/03 EN
90
MTC - Functions:
Both lifting axes can be moved to the service position.
Both feed axes can be moved to the service position.
MTC - Tower functions:
Production data: The level change and operating hours parameters are displayed.
–MTC - Axes:
Machine data – Positions: Positions with feed axes. The "Zero point correction" parameter
has been replaced by zero point correction for cassette 1, zero point correction for cassette
2, zero point correction for cassette 3 and zero point correction for cassette 4
Zero point correction for cassette 5 (only shown for Tower 1 / MTC2)
The following parameter has been extended: Service position
Positions with lifting axis – New parameters Refill position, cassette 5 (only shown for Tower
1 / MTC2), transfer position for cassette 5 (only shown for Tower 1 / MTC2), service position
Machine data – Positioning data
Positioning data with feed axis – the following parameter has been extended: Removal
speed
Default values with feed axis – the following parameter has been extended: Default removal
speed
MTC - Settings
Teach zero point with feed axis: As of MTC2 (but also with MTC1 -> firmware update), the
zero point correction of the feed axis must be taught for each cassette.
The checking of the zero point (cassette 1) for all other cassettes that has been carried out
until now is no longer required.
MTC - Inputs/outputs 1/2
The following new inputs have been taken into consideration: Input byte 3 / bit 4 = "Extra
high waffle pack tray" (only MTC2/Tower1), input byte 3 / bit 5 = "Lifting axis belt
monitoring", input byte 3 / bit 6 = "Battery voltage OK"
SIPLACE Software Guide SR.504.xx 8 New functionality in 504.01
Issue 01/03 EN 8.8 GEM 504
91
8.7.1 Mapping
The following modifications have been made for version 504 of the software: 8
Adaptations to the modular conveyor of the SIPLACE HF: Automatic introduction of the
mapping plate.
Glass mapping plate: The new mapping plate can be used for both the single conveyor and
(by rotating it through 90° and then inserting it) for the dual conveyor on the HF machine. The
previously available mapping plates will continue to be supported.
Selecting the appropriate camera: In the event of the presence of both an FC and an IC
camera, the calibration service decides automatically which of the cameras is to be used for
the mapping process. If both cameras are available, the FC camera is used.
Logging: Comprehensive logging procedures.
Reference to the reference corner: The first mapping point is now relative to the reference
corner. Thus it is impossible for the first mapping position not to be found.
NOTE
A detailed description of the mapping functions can be found in the Software Instructions for
SITEST 504. 8
8.8 GEM 504
All changes to the GEM 504 software since GEM 503 have been made in order to integrate the
new Twin Head and to reflect the change to µm. 8