00193697-01 - 第93页

SIPLACE S oftware Guide SR.504.xx 8 New functionality in 504.01 Issue 01/03 E N 8.1 0 Emergency stop without PCB check 93 8.9.1 Functionality/restrict ions when usi ng the "Safe mode" option with an open cover …

100%1 / 106
8 New functionality in 504.01 SIPLACE Software Guide SR.504.xx
8.9 Slow travel of the main axes and star with closed cover Issue 01/03 EN
92
8.9 Slow travel of the main axes and star with closed
cover
Since the SIPLACE HF no longer has a key switch, there is a new software option which makes
an analogous machine key switch functionality available. 8
This function is called with Options --> Run options... --> and the check box Safe mode
(reduced speed). 8
If the box has been checked, the gantries and star axes travel slowly (at approximately 10% of
the maximum speed). Reduced speed mode is activated. 8
If the check box is deactivated, all axes travel with the maximum possible speed. Reduced speed
mode is deactivated. 8
8
Fig. 8.9 - 1 Run options
NOTE
The "Safe mode (reduced speed)" is only available on the "Line engineer" and "Service engineer"
access levels. 8
SIPLACE Software Guide SR.504.xx 8 New functionality in 504.01
Issue 01/03 EN 8.10 Emergency stop without PCB check
93
8.9.1 Functionality/restrictions when using the "Safe mode" option with an open
cover
It is possible to carry out vacuum and forced air measurement for the revolver head and Twin
Head
It is possible to confirm nozzles, magazines and garages for the RV head and Twin Head
It is possible to activate the locking mechanism (open/shut) for the RV nozzle changer
All functions that involve the main axes are locked
All axis functions for the revolver head, for example, stepping the star axis, rotating the DP axis
etc. are locked
All axis functions for the Twin Head, for example, segment or head reference run, rotating the
DP axis, are locked
8.10 Emergency stop without PCB check
In the past, if an emergency stop occurs during placement (emergency stop button, compressed
air failure, cover is opened) the board in the output conveyor always needed to be checked and
the placement process then continued. 8
As of version 504 of the software, this behavior can be deactivated in the machine options (as of
line engineer access level). In the event of an emergency stop, this is indicated in the dialog box
which opens. 8
8 New functionality in 504.01 SIPLACE Software Guide SR.504.xx
8.10 Emergency stop without PCB check Issue 01/03 EN
94
8
Fig. 8.10 - 1 Machine options
8
Fig. 8.10 - 2 Machine stop