00197815-04_JC_PM_WF2_SX12_EN - 第37页
10 WF2 SX1/2 Clean the stationary camera (CPP / TH). 1 min 1 / 1 C A U T I O N ! R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c o m m e n c i n g M a i n t e n a n c e Machine S…

www.asm-smt.com

10 WF2 SX1/2 Clean the stationary camera (CPP / TH). 1 min 1 / 1
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Transport Empty
NOTICE! ESD guidelines are to be followed Tool: Wear Part: Consumables:
C2
www.asm-smt.com
1 Move both gantries to the end limit. 2 Take out the upper section of the IC-cam-
era.
3 Clean the slanted glass.
4 Refit the upper section of the camera. 5 Ensure the upper section is mounted to
the lower section it belongs to.

www.asm-smt.com