00197815-04_JC_PM_WF2_SX12_EN - 第38页

www.asm-smt.com

100%1 / 86
10 WF2 SX1/2 Clean the stationary camera (CPP / TH). 1 min 1 / 1
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Transport Empty
NOTICE! ESD guidelines are to be followed Tool: Wear Part: Consumables:
C2
www.asm-smt.com
1 Move both gantries to the end limit. 2 Take out the upper section of the IC-cam-
era.
3 Clean the slanted glass.
4 Refit the upper section of the camera. 5 Ensure the upper section is mounted to
the lower section it belongs to.
www.asm-smt.com
11 WF2 SX1/2 Prepare the feeder, return all tables, close the covers and switch on
machine.
1.25 min 1 / 2
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Transport Empty
NOTICE! ESD guidelines are to be followed Tool:
T1, T18
Wear Part: Consumables:
www.asm-smt.com
1 Remove all loose components from the
feeder modules.
2 Cut the remaining tape directly at the
feeder.
3 After Cutting: Ensure to leave 2 holes
overlapping.
4 Return all COT. 5 Close all covers. 6 Switch on the machine.