12 WF2 SX1/2 If required calibrate the head exchanged. 0.5 min 1 / 1
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Transport Empty
NOTICE! ESD guidelines are to be followed Tool:
T2, K01
Wear Part: Consumables:
C3
www.asm-smt.com
1 If no head has been replaced proceed with
next task or calibrate accordingly.
2 For C&P heads, see appendix "Calibrate
the maintained C&P head" [27]
.
3 For TwinHeads, see appendix "Calibrate
the maintained TwinHead" [28]
.
www.asm-smt.com
13 WF2 SX1/2 Check the filter discs of all C&P20x. 3 min 1 / 1
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Transport Empty
NOTICE! ESD guidelines are to be followed Tool: Wear Part: Consumables:
www.asm-smt.com
1 Click on "Check filter discs". 2 Click on "Move in all component tables", if
required.
3 Press the start button.
4 Check if result is OK (green hook). 5 If result is not OK (red cross) contact ser-
vice.