21 WF2 SX1/2 Appendix: Calibrate the maintained C&P head 4.5 min 1 / 5 C A U T I O N !  R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c o m m e n c i n g M a i n t e n a n c e…

100%1 / 86
www.asm-smt.com
21 WF2 SX1/2 Appendix: Calibrate the maintained C&P head 4.5 min 1 / 5
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Transport Empty
NOTICE! ESD guidelines are to be followed Tool:
T2, K01
Wear Part: Consumables:
C3
www.asm-smt.com
1 Open the cover. 2 Insert the calibration tool for C&P20x (T4)
or CPP (T5).
3 Close all covers.
4 Click on "Settings and options". 5 Click on "User settings". 6 Click on "Machine service" and "Cali-
bration".
21 WF2 SX1/2 Appendix: Calibrate the maintained C&P head 4.5 min 2 / 5
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Transport Empty
NOTICE! ESD guidelines are to be followed Tool:
T2, K01
Wear Part: Consumables:
C3
www.asm-smt.com
7 Click on "Fast hardware exchange". 8 Click on "Head exchange". 9 Select the head to be calibrated, "Brief
calibration" and click on "Next".
10 Click on "Start". 11 Click on "Move in all component tables". 12 Press the start button.