semi合集-English.pdf - 第1318页
SEMI E5-1104 © SEMI 1982, 2004 260 R1-3.2.2 The trace feature will onl y exist in equipm ent which implements it. R1-3.2.3 The host sets up the trace wit h the S2,F23-24 transaction. At this time, the host assigns severa…

SEMI E5-1104 © SEMI 1982, 2004 259
RELATED INFORMATION 1
APPLICATION NOTES
NOTICE: The material contained in this Related Information section is not an official part of SEMI E5 and is not
intended to modify or supersede the official standard. Rather, these notes describe possible methods for
implementing the protocol described by the standard and are included as reference material. The standard should be
referred to in all cases. SEMI makes no warranties or representations as to the suitability of the material set forth
herein for any particular application. The determination of the suitability of the material is solely the responsibility
of the user.
R1-1 The General Node Transaction Protocol
R1-1.1 This application note has been moved to follow
SEMI E4 (SECS-I) as Application Note A7.
R1-2 Some Suggested Message Usage
R1-2.1 The number of messages implemented and the
choice of messages are greatly influenced by the actual
function of the equipment. To illustrate which
messages might be appropriate, the following
suggestions are offered for a variety of different types
of equipment capabilities. It is assumed that the
minimum message sets S1,F1; F2 and S9,F1; F3; F5;
F7 are always implemented.
R1-2.2 For equipment which makes nondestructive in-
process measurements using a fixed measurement
procedure, it may be necessary only to implement S6,
F9 to send the data according to a fixed format upon
measurement. Optional remote control can be added
with S2,F21 to start a measurement.
R1-2.3 If the equipment has a variety of measurement
routines, it might be desirable to respond to S1,F5 with
S1,F6, which would give the host a brief report of the
test being made. The test can be thought of as a process
program. Accordingly, S7,F1 and S7,F2 could be used
for the host to select the program. The same messages
in conjunction with S7,F3 and S7,F4 could load a new
test procedure. S7,F19 could be used by the host to
find out what tests were available.
R1-2.4 Some equipment which automatically processes
wafers in a batch might make more extensive use of
S1,F5 or S1,F3 and might include some error reporting
on S5,F1. More sophisticated equipment may include
some trace features with S2,F23 and S6,F1 or some
control loop tuning by S2,F15.
R1-2.5 Equipment using in-line wafer movement could
utilize Stream 4, S1,F9, and Stream 3 to keep track of
wafers.
R1-2.6 Stream 7,F9 through F19 can be used to
manage a local backup of process programs should the
host fail for a short while.
R1-2.7 Microprocessor equipment can benefit from
features such as provided by Stream 8 and S2,F1
through F12 which allow managing and servicing the
software routines.
R1-2.8 Equipment, including a CRT, might elect to
make it available to the host by including Stream 10
messages.
R1-2.9 Some equipment, such as functional testers,
might have sufficient need to undertake remote file
usage such as provided in Stream 13.
R1-2.10 These brief suggestions serve to illustrate that
the final choice of the messages included in a given
equipment depends upon its function. The messages
can be viewed as interface features in the same way that
other parts of the equipment are viewed as processing
features or wafer handling features.
R1-3 Notes on SECS-II Data Transfers
R1-3.1 Introduction
R1-3.1.1 There are two primary ways to send and ask
for data in SECS-II. One of these is to use the trace
feature and the other is to use the event reporting
method. The purpose of this note is to describe the
intended operation of the messages described in the
existing standard. Discussion of completeness or need
for other reporting methods is left for task force and
committee work.
R1-3.2 Trace Data Collection and Reporting
R1-3.2.1 This method of collecting data is intended for
engineering and developmental use rather than routine
data collection for production. The features included
allow the collection of relatively large amounts of real
time data over a finite amount of time. The data is
generated at regular time intervals as determined by a
timing generator in the equipment. The function of the
host is to set up the trace and then to subsequently store
the data as it is received from the equipment. It is
assumed that some host resident applications will exist
to analyze the data either as it is received or at some
later time.

SEMI E5-1104 © SEMI 1982, 2004 260
R1-3.2.2 The trace feature will only exist in equipment
which implements it.
R1-3.2.3 The host sets up the trace with the S2,F23-24
transaction. At this time, the host assigns several
important parameters. TRID is the trace request ID and
is used later when the equipment sends back the data.
Every trace data reply includes the TRID corresponding
to the request that set up the trace. Several traces can
theoretically be done at the same time if the equipment
allows it and the TRID keeps the data for each trace
distinct from other trace data. DSPER is the data
sample period and is used to indicate how often the
specified parameters should be sampled (that is, have
their values saved). TOTSMP is the total number of
samples to be made. Since TOTSMP is finite and the
number of parameters is specified in this transaction,
the host can reserve adequate file space for the reported
data if required. The REPGSZ is the reporting group
size and corresponds to the number of time samples that
should be combined into one message prior to
transmission. Thus, if it is desired to sample one or two
parameters every second but only send those samples to
the host once a minute, the reporting group size would
be 60. Having the reporting group size parameter
allows the host to have some control over how often it
may be interrupted to handle the trace data. However,
as presently defined in the standard, the trace data is
reported as a single block message (S6,F1), which
restricts both the number of status variables or the
number of samples which can be combined into one
message. The equipment may be able to accommodate
this in several ways, to be described shortly.
R1-3.2.3.1 The last element in the trace initialize
request is a list of status variable IDs. The trace
command only allows tracing variables that have been
declared and are known to the equipment as status
variables. It is assumed that the equipment will report
the variable values in the same order as specified in the
trace request. This will allow the host to identify the
values returned.
R1-3.2.4 The trace data send message, S6,F1-2, sends
the trace data as a single block message to minimize the
overhead in reporting data. The TRID is the first item
and identifies the request that asked for the data. The
next item is SMPLN, the sample number of the last
sample in this message, should more than one sample
be combined. The next item is STIME which is the
time of the last sample in this message. These three
items are followed by the list of values. If five (5)
values were requested with a reporting group size of 5,
then 25 values would be in this list, each group of 5 in
the same order as requested and in the time order
sampled. Some flexibility is allowed in how the
equipment chooses to report the data to the host when
the reporting group size exceeds one block of data. The
equipment can send the data when it has a complete
block or it can reject the request when it is set up.
R1-3.3 Event Driven Data Reporting
R1-3.3.1 The second major type of data reporting is
initiated by some event in the equipment. Data
reporting is often desired after some event such as the
completion of a measurement, the completion of a lot,
the completion of a wafer, the occurrence of a special
event command in the recipe, or some other action
which is determined by the equipment. The two aspects
involved in event driven data reporting are the control
of which events cause data to be sent to the host and the
formatting of the data sent to the host.
R1-3.3.2 It is assumed that a set of events has been
established for a particular piece of equipment and that
each event can produce a report of some sort. It is
further assumed that a set of equipment constants exist
in the machine such that they have control over the
optional reporting of the events. For example, a
boolean constant may exist for each possible reporting
event, and when the host sets the constant to a logical 1,
the corresponding event will cause a report to be sent to
the host, when the host sets the constant to logical 0, the
event will not send a report. S2,F15-16 in the
equipment constant send transaction can be used to
control the event reporting.
R1-3.3.3 When an event causes data to be sent to the
host, there are several possible conversations,
depending upon the length of the data and the
complexity of the formatting. S6,F3-4 is the basic data
transaction, which has a very general format. The
parameters provide for an overall name, DATAID, for
the type of data; a collection event identification, CEID,
should there be more than one event that could generate
the same type of data; and a list of data sets. This
structure allows reporting such data as the
measurements taken on each of the wafers in a lot. The
measurements on each wafer make up one data set, and
the list of data sets is the whole lot. The collection
event would be the lot completion, and the data ID
might be film thickness measurements. Other types of
organizations are possible, depending upon the type of
data being sent. The same type of data might be
produced by a different CEID, such as the forced
termination of the lot. This collection ID would
indicate that the data is incomplete for the lot. Within
each data set, each data value is reported as a pair of
items, one item being the name of the value and the
other being the value.
R1-3.3.4 Since many simple measuring devices have
only a very few types of data sets, an alternative data
format is provided in S6,F9-10, which has the same

SEMI E5-1104 © SEMI 1982, 2004 261
form as S6,F3-4 but does not require the value name in
the data set. Instead, the order of the values is fixed
format for the particular DSID in that particular
equipment.
R1-3.3.5 When either of the above data messages is
long enough to require multiple blocks, it must be
preceded by S6,F5-6 to gain permission to send a
multiple block message.
R1-3.3.6 The last data control transaction is S6,F7-8,
which is initiated by the host and causes a specified
DATAID to be sent to the host. The implementation of
this function is highly equipment-dependent. In
essence, it is equivalent to the host causing an event
that triggers the sending of the data. Since the
equipment may be generating the data, the actual data
sent depend upon the equipment implementation. The
equipment can respond with a zero length item if no
data can be sent.
R1-3.4 Event Reporting
R1-3.4.1 The third major type of data reporting is
similar to that described in A3.3 above, with the
following enhancements:
1. Contents of data reports are not limited to
DVVALs, but may include SVs or even ECVs.
2. Contents of data reports are user programmable.
R1-3.4.2 It is assumed that the equipment vendor
supplies a list of all “events” identified within a
particular piece of equipment. A Collection Event
Identifier (CEID) must be specified for each of these
events. It is further assumed that the vendor supplies a
list of all available variables within the machine. This
includes Status Variables (SVs) and their identifiers
(SVIDs), Equipment constants (ECVs) and their
identifiers (ECIDs), and Data Values (DVVALs) and
their identifiers(DVNAMEs). Each of the identifiers
must be unique. The term VID (Variable Identifier)
encompasses all SVIDs, ECIDs, and DVNAMEs.
Likewise, the term V (Variable Data) encompasses all
SVs, ECVs, and DVVALs.
R1-3.4.3 Note that a Variable (V) may be a list (format
code 0). This provides for referencing a group of
related data values with one identifier. Consider the
following:
VID
1
= 1 zone 1 temperature ID Format 32
V
1
zone 1 temperature value Format 52
.
.
VID
n
= n zone n temperature ID Format 32
V
n
zone n temperature value Format 52
VID
x
= x all temperatures ID Format 32
V
x
L,n Format 0
1. L,2
1. <VID
1
>
2. <V
1
>
.
.
n. L,2
1. <VID
n
>
2. <V
n
>
Any V in a list may also be a list (for nesting).
R1-3.4.4 In a typical initialization sequence, the host
would define all the desired programmable data reports
with S2,F33/S2,F34 (Define Report) transactions. Then
S2,F35/S2,F36 (Link Report/Event) transactions would
be used to define which reports are to be made by the
equipment upon specific events (CEIDs). An
individual report may be linked to more than one event.
At this point the host may request reports with the
S6,F15/S6,F16 (Report Request) transactions to obtain
initial report data and/or to verify reports as defined and
linked. Finally, the desired reports would be enabled
by the host with S2,F37/S2,F38 (Enable/Disable Event
Report) transactions.
R1-3.4.5 There are two methods for the equipment to
send event reports to the host. S6,F13 includes the
Variable Identifier (VID) with each Variable Data item
(V). S6,F11 is a shorter form, without the identifiers;
some users prefer this form to reduce message size.
R1-3.4.6 When any message is long enough to require
multiple blocks, it must be preceded by an inquire/grant
transaction.The DATAID parameter is used only to link
the inquire/grant transaction with a multiblock message.
This linkage is to alleviate problems in the case of
interleaved messages. A unique value for DATAID
must be used for each Inquire/Grant/Send/Ack-
nowledge conversation (similar to the use of
SYSBYTES in SECS-I). The DATAID parameter
should not be used for any other purpose.
R1-4 Process Programs
R1-4.1 Introduction
R1-4.1.1 Two forms of process programs are supported
by SECS-II: unformatted and formatted. The contents
of an unformatted process program conform to no set
standard. The format of the program is defined by the
vendor of the equipment and probably bears no