SEMI E30-1103 © SEMI 1992, 2003
34
4.4 Remote Control
4.4.1 Purpose — This capability provides the host with
a level of control over equipment operations.
4.4.2 Definitions
Host Command Parameter (CPNAME/
CPVAL/CEPVAL) — A parameter name/value
associated with a particular host command
(S2,F41/S2,F49). The equipment manufacturer must
provide unique names (CPNAMEs) for any supported
command parameters. Command parameters are not
specified in this document but are left to equipment
manufacturers to define. Equipment models of specific
classes of semiconductor equipment also may address
this issue. Note that if there are no associated
parameters a zero-length list is sent. The data item
CEPVAL, which can be defined as a list, allows
grouping of related parameters within a main
parameter. If the CEPVAL is defined as a single (non-
list) item, then it is the equivalent of a CPVAL.
The uses of OBJSPEC in the header structure of the
S2,F49 Enhanced Remote Command allows the
equipment supplier to define a set of unique identifiers
for different objects within the equipment such as:
equipment sub-systems, sub-system components,
processing stations, ports, and exchange stations.
4.4.3 Description — The equipment responds to host
commands that provide the following functions relative
to individual equipment implementations:
— Start processing
Select a process program or recipe
— Stop processing
Temporarily suspend processing
— Resume processing
— Abort processing
Additional commands may be implemented by the
equipment manufacturer (e.g., vent chamber, clear
material, open door).
Remote commands shall be interpreted as “request
action be initiated” rather than “do action.” The
equipment may then respond via S2,F42/S2,F50 with
HCACK = 4 if the command “is going to be
performed.” This alleviates any transaction timeouts
for commands that may take a long time to perform.
The completion of the action initiated by the remote
command (i.e., HCACK = 0 or 4) must result in either a
state transition or other action that generates a
collection event upon normal/abnormal completion.
The format for all remote commands is ASCII, with a
maximum length of 20 characters. The character set is
restricted to the printable characters (hexadecimal 21
through 7E). Note that spaces are not allowed.
The following remote commands (RCMDs), if
implemented on the equipment, shall be supported as
described below (see Section 3.4 for a description of
Equipment Processing States).
NOTE 12: The terms “current cycle” and “safe break point”
used below are to be defined by the supplier or within the
models of classes of semiconductor equipment.
START — This command is available to the host when
a process program or recipe has been selected and the
equipment is in the “ready” processing state. The
START command instructs the equipment to initiate
processing. Variable parameter settings may be
included as name/value command parameters
CPNAME/CPVAL/CEPVAL.
PP-SELECT — This command instructs the equipment
to make the requested process program(s) available in
the execution area. The process programs (PPIDs) are
specified via the command parameter list. A status
variable (PPExecName) contains the PPID of the
process program(s) currently selected.
RCP-SELECT — This command uses the Enhanced
Remote Command S2,F49 to instruct the equipment to
prepare the requested recipes for execution in the
execution area. The recipes and variable parameters are
specified via command parameter lists. Each recipe
specification may be accompanied by new variable
parameter settings, if any, in the command parameter
list. A status variable RcpExecName contains the
recipe specifiers or identifiers of the recipes currently
selected.
STOP — Command to complete the current cycle, stop
in a safe condition and return to the “idle” processing
state. Stop has the intent of stopping the process. The
equipment is not required to support the continuation of
processing. Stop leaves material either fully processed
or partially processed so that the processing can be later
completed. For example, for a single wafer process
tool, five wafers have been processed while the
remaining wafers remain unprocessed.
PAUSE — Command to suspend processing
temporarily at the next safe break point. Pause has the
intent of resuming the process at the same point where
it was paused. The process may be RESUMED,
STOPPED, or ABORTED while in a PAUSED
condition. RESUME shall be able to continue the
process from the same point where it was paused.
SEMI E30-1103 © SEMI 1992, 2003
35
RESUME — Command to resume processing from the
point where the process was paused.
ABORT — Command to terminate the current cycle
prior to its completion. Abort has the intent of
immediately stopping the process and is used because
of abnormal conditions. Abort makes no guarantee
about the subsequent condition of material. In the
above example, the wafers being processed at the time
of the abort may not be completely processed. Other
AbortLevels > 1 may be defined by the manufacturer or
addressed by models of specific classes of
semiconductor equipment.
CPNAME = AbortLevel, CPVAL = 1 means terminate
current cycle at the next “safe break point,” retrieve all
material, stop in a safe condition and return to the idle
state in the processing state machine.
4.4.4 Requirements
The following Remote Commands, as defined under
Descriptions, must be implemented on equipment to
satisfy minimum requirements for this capability:
— START
— STOP
The RCMD value for all commands supported on
the equipment must be recognized if sent with all
upper-case characters (e.g., “STOP”, “START”,
“PP-SELECT”, “PAUSE”, etc.). In addition to
accepting strings with all upper-case characters, the
equipment can optionally accept strings with all
lower-case characters or mixed-case strings. The
equipment documentation should describe whether
or not the optional lower-case or mixed-case strings
are supported.
Stream 2 currently provides for Host Command
Send and Enhanced Remote Command. The
equipment shall support one or both methods, based
on appropriateness.
The Enhanced Remote Command is used to address
size, complexity, or the need to target a specific sub-
system within the equipment, (i.e., processing
station, port, exchange station, material handler,
chamber).
4.4.5 Scenarios
4.4.5.1 Host Command Send Scenario
COMMENTS HOST EQUIPMENT COMMENT
Host Command Send S2,F41-->
<-- S2,F42 Host Command Acknowledge
[IF] Command Accepted
(HCACK = 0 or 4)
<-- S6,F11 [THEN] Event Report-state
change or other collection
event occurrence.
Event Report Acknowledge S6,F12-->
SEMI E30-1103 © SEMI 1992, 2003
36
4.4.5.2 Enhanced Remote Command Scenario
COMMENTS HOST EQUIPMENT COMMENT
Enhanced Remote Command S2,F49-->
<--S2,F50 EnhancedRemote Command
Acknowledge
[IF] Command Accepted
(HCACK = 0 or 4)
<--S6,F11 [THEN] Event Report-state
change or other collection
event occurrence.
Event Report Acknowledge S6,F12-->
4.5 Equipment Constants
4.5.1 Purpose — This capability provides a method for
the host to read and to change the value of selected
equipment constants on the equipment.
4.5.2 Definitions — None.
4.5.3 Description — This capability allows the host to
reconfigure equipment constants to support a variety of
situations. The following functions are included:
Host Sends Equipment Constants — Allows the host to
change the value of one or more equipment constants.
Host Equipment Constant Request — Allows the host
to determine the current value of equipment constants.
Host Equipment Constant Namelist Request — Allows
the host to retrieve basic information about the
equipment constants available at the equipment.
4.5.4 Requirements
Equipment constants must be stored in non-volatile
memory.
The equipment must be in a “safe” condition to
accept new constant(s) settings as defined by the
equipment manufacturer.
The equipment must provide a collection event to
alert the host whenever an equipment constant is
changed by the operator. Information indicating
which constant was changed shall be available for
the event report.
4.5.5 Scenarios
Host Sends Equipment Constants:
COMMENTS HOST EQUIPMENT COMMENTS
Host sends S2,F15-->
equipment constants <-- S2,F16 EAC = 0 equipment sets
constants
Host Equipment Constants Request:
COMMENTS HOST EQUIPMENT COMMENTS
Host constant request S2,F13-->
<-- S2,F14 Equipment constant data
NOTE: This capability also can be accomplished using S6,F19 & S6,F20. See Section
4.2.