SEMI F59-0302 © SEMI 2000, 2002 3 for pressu re drop measurem ent. The gas stick m ay be removed from the pallet to attach to the test fixture. 11.2 Pressure regul ators and MFCs s hall be m aintain ed in their fu lly op…

SEMI F59-0302 © SEMI 2000, 2002 2
5.1.15 s second
5.1.16 scfm standard cubic feet per minute
5.1.17 slpm standard liters per minute
5.1.18 T (K) temperature in Kelvin
5.1.19
∆
P differential pressure in kPa
5.1.20
∆
P(Housing) (kPa, differential) differential
pressure of housing in kiloPascal, differential
5.1.21
∆
P(Unit) (kPa, differential) differential
pressure of filtration unit in kiloPascal, differential
5.1.22
∆
P(cartridge) (kPa, differential) differential
pressure of cartridge element in kiloPascal, differential
5.2 Definitions
5.2.1 filter cartridge the filtration element.
5.2.2 filter housing the shell that contains the filter
cartridge.
5.2.3 filtration unit the assembly consisting of a
filter cartridge and housing.
5.2.4 gas box — a gas distribution subsystem which
generally contains the final shut-off valve(s) prior to the
POC.
5.2.5 gas pallet — individual gas distribution
subsystems within a gas box that control flow of gas to
individual process chambers.
5.2.6 gas stick — a series of components for an
individual gas within a gas box. It may contain valves,
a regulator, a pressure transducer, a purge line, an
MFC, and a filter.
5.2.7 integral unit the filter cartridge and housing
are not separable.
5.2.8 normal conditions 101.3 kPa (14.7 psia) and
ambient temperature conditions 293.15 K (20
o
C).
5.2.9 separable unit the filter cartridge and housing
can be disassembled.
5.2.10 spool flow through component — a null
component consisting of an electropolished flow
passage and appropriate fittings used in place of the test
component.
5.2.11 standard conditions 101.3 kPa, 273.15 K
(14.7 psia, 0
o
C).
6 Summary of Method
6.1 This test method describes the test equipment and
procedures for determining the flow pressure drop of
filters or gas systems. The differential pressure is
measured across a DUT at various inlet pressures and
flows. If the filtration unit is separable the individual
contributions from the housing and cartridge are
determined.
7 Interferences
7.1 Test stand must be of adequate dimensions so that
it does not limit the flow through the test DUT. The
pressure drop for the test stand must be insignificant
compared to the pressure drop for a DUT at the test
flow rate.
8 Apparatus
8.1 pressure regulator
8.2 downstream flow regulating valve
8.3 flow meter capable of measuring flow rates to
better than 5% full scale and of appropriate range.
8.4 several pressure transducers or gauges
8.5 differential pressure transducer (0.67 kPa, (0.1 psi)
sensitivity)
8.6 Test stand
8.7 Temperature measuring device (
o
C)
9 Reagents and Materials
9.1 Test Gas nitrogen or CDA filtered to < 0.02
micrometer with a dew point of less than or equal to –
40
o
C.
10 Safety Precautions
10.1 Safety Precautions This test method may
involve hazardous materials, operations, and
equipment. This test method does not purport to
address all of the safety problems associated with its
use. It is the responsibility of the user to establish
appropriate safety and health practices and to determine
the applicability of regulatory limitations prior to its
use.
10.2 The user must have a working knowledge of the
respective instrumentation, must practice proper
handling of test components, and must understand good
laboratory practices. The user should not operate the
components in such a manner as to exceed the ratings
(i.e., pressure, temperature, flow and voltage).
11 Test Specimen
11.1 A gas box may consist of several gas pallets that
uniquely control flow of gases to a specific process
chamber. More than one gas stick layout is possible on
the pallet. The user shall test only one stick at a time

SEMI F59-0302 © SEMI 2000, 2002 3
for pressure drop measurement. The gas stick may be
removed from the pallet to attach to the test fixture.
11.2 Pressure regulators and MFCs shall be maintained
in their fully open position during testing.
11.3 When comparing different gas system designs, it
is useful to use components of similar design.
11.4 If the stick design contains a filter that dominates
the pressure drop on the system, such filters shall be
replaced by spool flow through components
12 Preparation of Apparatus
12.1 Construct a test stand for the measurement of gas
flow rates and pressure drop across a DUT. Examples
of such a test stand are shown in Figures 1a or 1b as
schematic drawings.
12.2 The gas supply is filtered by an electronics grade
high purity point-of-use gas filter before it is delivered
to the DUT through a pressure regulator.
12.3 A flow meter can be installed either upstream or
downstream of the DUT. See Figures 1a or 1b. The
test filter is upstream of a throttle valve to allow for
control of the flow through the DUT.
12.4 Inlet pressure is measured immediately upstream
of the DUT by a pressure gauge or pressure transducer.
12.5 Pressure drop across the test specimen is
measured by an electronic differential pressure
transducer capable of reading 0.67 kPa (0.1 psid) across
the test device.
12.6 Flow measurements are carried out through a flow
meter installed upstream or downstream of the test
filter. See Figures 1a or 1b.
NOTE 2: The flow measurement can be influenced by both
upstream and downstream pressure fluctuations. It is
necessary to verify the accuracy of any flow measurement
under the test conditions used to complete this testing.
12.7 A temperature measurement device can be
installed in the test stand to measure the gas stream
temperature.
12.8 Figure 2 gives the piping requirements for the test
stand configuration.
12.9 Figure 3 gives the recommended pressure
connection to be followed in constructing the test
apparatus.
13 Calibration and Standardization
13.1 For each test, verify that calibration of test
equipment is up-to-date.
13.2 A series of flow meters should be used to cover
the full range of flows that will be tested.
14 Procedure
14.1 Integral Filtration Unit
14.1.1 Assemble the filtration unit into the test
apparatus. (See Figure 1.)
14.1.2 Set the inlet pressure using the pressure
regulator to 10% of the filter’s maximum rated inlet
pressure or to 205 kPa (29.7 psia) whichever is less.
Pressure is read on the inlet pressure gauge.
14.1.3 Adjust the flow rate using the regulating valve
to give 10 % of the maximum rated flow. Adjustments
to the inlet pressure regulator may be required to
maintain a constant inlet pressure of 205 kPa (29.7
psia). The flow and pressure adjustments can be an
iterative process requiring several iterations to achieve
the desired flow rate and inlet pressure. The flow rate
is read on the flow meter and recorded.
14.1.4 Read and record the ambient temperature, inlet
pressure, pressure drop across the test filter, ambient
pressure, and flow rate corrected for upstream pressure
based on manufacturer’s recommendation.
14.1.5 Repeat steps in Sections 14.1.3 and 14.1.4 at
25%, 50%, 75% and 100% of the maximum rated flow.
14.1.6 Repeat steps in Sections 14.1.2 through 14.1.5
at several inlet pressures: 309 kPa (44.7 psia), 516 kPa
(74.7 psia), and 723 kPa (104.7 psia).
14.1.7 Additional testing of the filter at higher
pressures can be completed up to the maximum rated
pressure.
14.1.8 When the filter has a lower maximum pressure
rating than 90 psig, it is recommended that the filter be
tested at pressures of 33%, 67% and 100% of the
filter’s maximum pressure rating, with tests being
limited by the sensitivity of the differential pressure
device.
14.2 Separable Filtration Unit - Filter Housing
14.2.1 Assemble the empty filter housing into the test
apparatus.
14.2.2 Set the inlet pressure using the pressure
regulator to 10% of the housing’s maximum rated inlet
pressure or to 205 kPa (29.7 psia) whichever is less.
The inlet pressure is read on the inlet pressure gauge
and recorded.
14.2.3 Adjust the flow rate using the regulating valve
to give 10% of the maximum rated flow. Adjustments
to the inlet pressure regulator may be required to
maintain a constant inlet pressure of 205 kPa (29.7
psia). The flow and pressure adjustments can be an
iterative process requiring several iterations to achieve

SEMI F59-0302 © SEMI 2000, 2002 4
the desired flow rate and inlet pressure. The flow rate
is read on the flow meter and recorded.
14.2.4 Read and record the ambient temperature,
ambient pressure, inlet pressure, pressure drop across
the test filter, and flow rate corrected for upstream
pressure based on manufacturer’s recommendation.
14.2.5 Repeat steps in Sections 14.2.3 and 14.2.4 at
25%, 50%, 75%, 100% of the filter cartridge’s
maximum rated flow.
14.2.6 Repeat steps in Sections 14.2.2 through 14.2.5
at several inlet pressures. For example, test at 309 kPa
(44.7 psia), 516 kPa (74.7 psia), and 723 kPa (104.7
psia).
14.2.7 Additional testing of the filter at higher
pressures can be completed up to the maximum rated
pressure.
14.2.8 When the filter has a lower maximum pressure
rating than 90 psig, it is recommended that the filter be
tested at pressures of 33%, 67% and 100% of the
filter’s maximum pressure rating, with tests being
limited by the sensitivity of the differential pressure
device.
14.3 Separable Filtration Unit – Assembled Cartridge
and Housing
14.3.1 Assemble the filter cartridge into the filter
housing.
14.3.2 Assemble the filtration unit into the test
apparatus.
14.3.3 Set the inlet pressure using the pressure
regulator to 10% of the filter’s maximum rated inlet
pressure, or to 205 kPa (29.7 psia), whichever is less.
The inlet pressure is read on the inlet pressure
gauge/transducer and recorded. This pressure should be
the same as used for the filter housing test in Section
14.2.2.
14.3.4 Adjust the flow rate using the regulating valve
to give 10% of the maximum rated flow. Adjustments
to the inlet pressure regulator may be required to
maintain a constant inlet pressure of 205 kPa (29.7
psia). The flow and pressure adjustments can be an
iterative process requiring several iterations to achieve
the desired flow rate and inlet pressure. The flow rate
is read on the flow meter and recorded. This should be
the same as used for the filter housing test in Section
14.2.3.
14.3.5 Read and record the ambient temperature,
ambient pressure, inlet pressure, pressure drop, and
flow rate.
14.3.6 Repeat steps in Sections 14.3.3 and 14.3.5 at
25%, 50%, 75% and 100% of the maximum rated flow.
These should be the same flow settings as used in
Section 14.2.5.
14.3.7 Repeat steps in Sections 14.3.2 through 14.3.6
at several inlet pressures. For example, test at 309 kPa
(44.7 psia), 516 kPa (74.7 psia), and 723 kPa (104.7
psia).
14.3.8 Additional testing of the filter at higher
pressures can be completed up to the maximum rated
pressure. These inlet pressure settings should be the
same as used in Section 14.2.7.
14.3.9 When the filter has a lower maximum pressure
rating, it is recommended that the filter be tested at
pressures of 33%, 67% and 100% of the filter’s
maximum pressure rating, with tests being limited by
the sensitivity of the differential pressure device.
14.3.10 The flow curve for the filter cartridge is
determined by subtracting the pressure drop of the
housing from the pressure drop of the assembled
filtration unit at respective flow rates and inlet test
pressures.
14.4 Gas System
14.4.1 Assemble the DUT into the test apparatus. (See
Figure 1.)
14.4.2 Set the inlet pressure using the pressure
regulator to 205 kPa (29.7 psia). Pressure is read on the
inlet pressure gauge.
14.4.3 Adjust the flow rate using the regulating valve
to give 1 slpm. Adjustments to the inlet pressure
regulator may be required to maintain a constant inlet
pressure of 205 kPa (29.7 psia). The flow and pressure
adjustments can be an iterative process requiring
several iterations to achieve the desired flow rate and
inlet pressure. The flow rate is read on the flow meter
and recorded.
14.4.4 Read and record the ambient temperature, inlet
pressure, pressure drop across the DUT, ambient
pressure, and flow rate.
14.4.5 Repeat steps in Sections 14.4.2 through 14.4.4
at flow rates of 5, 10, 25, 50, 75, and 100 slpm.
14.4.6 Repeat steps in Sections 14.4.2 through 14.4.5
at several inlet pressures: 308 kPa (44.7 psia), 515 kPa
(74.7 psia), and 791 kPa (114.7 psia).
14.4.7 Additional testing of the DUT may be
performed at higher pressures up to the maximum rated
pressure. Where components are not specified to
operate at the required flow rates and pressures listed in
Sections 14.4.5 and 14.4.6 then tests shall be performed
to the highest pressures and flows attainable while
remaining within the component’s maximum operating
specification.