SEMI C23-0301 © SEMI 1981, 2001 BUFFERED OXIDE ETCHANTS2
7.2 For the example above, the permissible range of
concentration for ammonium fluoride shall be 34.8 ±
0.5% and for hydrofluoric acid 6.33 ± 0.15%.
8 Requirements
8.1 The requirements for buffered oxide etchants for
Grades 1 and 2 are listed in Table 1.
9 Grade 1 Procedures
9.1 Hydrofluoric Acid — Weigh accurately
approximately 4.0 grams of sample, transfer to a
polyethylene beaker, and dilute with water to about 100
mL. Titrate with standardized 1 N sodium hydroxide.
The endpoint may be detected colorimetrically by
adding 3 drops of methyl red indicator solution and
titrating to a definite yellow (no orange) endpoint. As
an alternate method, the endpoint may be detected
potentiometrically using an HF resistant pH electrode
previously standardized in pH 4 and pH 7 buffers.
Titrate to pH 6.5 with continuous stirring. Save the
solution for the determination of ammonium fluoride.
% Hydrofluoric Acid
=
mL
×
N
of
N
aOH
×
2.001
Weight of sample g
()
9.2 Ammonium Fluoride — Add 40 mL of neutralized
formaldehyde solution (see Section 9.2.1) to the
solution from the preceding test and stir magnetically
for 30 minutes. Titrate with standardized 1 N sodium
hydroxide. The endpoint may be detected
colorimetrically using 10 drops of phenolphthalein
indicator and titrating to a stable pink end point. As an
alternative method, the endpoint may be detected
potentiometrically using an HF resistant electrode
previously standardized in pH 7 and 9 buffers. Titrate
to pH 8.5 with continuous stirring.
%
Ammonium Fluoride
=
mL
×
N
of NaOH
×
3.704
Weight of sample g
()
9.2.1 Neutralized Formaldehyde Solution — Dilute 20
mL of 37% formaldehyde solution with 20 mL of water
and neutralize with 0.1 N sodium hydroxide solution to
the phenolphthalein endpoint.
9.3 Arsenic and Antimony (as As) To 30 mL (33 g)
of sample in a polyfluorocarbon dish, add 20 mL of
nitric acid and 5 mL of hydrochloric acid and evaporate
in a sand bath in a hood to dryness. Completely
volatilize the ammonium fluoride, but do not bake. Add
10 mL of water and 5 mL of sulfuric acid and evaporate
to dense fumes of sulfur trioxide. Cool, cautiously add
10 mL of water, and reevaporate to dense fumes of
sulfur trioxide. Cool, and cautiously wash into a
generator flask with water to make a volume of 35 mL.
Proceed as described in the General Method for Arsenic
(and Antimony) under SEMI C1, Section 3.4.5, starting
with the sentence which begins, “Swirl the flask...” Any
red color in the silver diethyldithiocarbamate solution
of the sample should not exceed that in the standard
containing 0.001 mg of arsenic ion (As).
9.4 Trace Element Contents — Determine the levels
of specified trace elements and establish that they do
not exceed the specification limits using a suitable
emission spectrographic procedure (see SEMI C1,
Section 3.5, Guidelines for Determination of Trace
Elements by Emission Spectrography).
10 Grade 2 Procedures
NOTE 1: Each laboratory is responsible for verifying the
validity of the method within its own operation.
10.1 Hydrofluoric Acid Weigh accurately
approximately 4.0 grams of sample, transfer to a
polyethylene beaker, and dilute with water to about 100
mL. Titrate with standardized 1 N sodium hydroxide.
The endpoint may be detected colorimetrically by
adding 3 drops of methyl red indicator solution and
titrating to a definite yellow (no orange) endpoint. As
an alternate method, the endpoint may be detected
potentiometrically using an HF resistant pH electrode
previously standardized in pH 4 and pH 7 buffers.
Titrate to pH 6.5 with continuous stirring. Save the
solution for the determination of ammonium fluoride.
% Hydrofluoric Acid =
mL
×
N
of
N
aOH
×
2.001
Weight of sample (g)
10.2 Ammonium Fluoride Add 40 mL of
neutralized formaldehyde solution (see Section 10.2.1)
to the solution from the preceding test and stir
magnetically for 30 minutes. Titrate with standardized 1
N sodium hydroxide. The endpoint may be detected
colorimetrically using 10 drops of phenolphthalein
indicator and titrating to a stable pink endpoint. As an
alternative method, the endpoint may be detected
potentiometrically using an HF resistant electrode
previously standardized in pH 7 and 9 buffers. Titrate to
pH 8.5 with continuous stirring.
% Ammonium Fluoride =
mL
×
N
of
N
aOH
×
3.704
Weight of sample (g)
10.2.1 Neutralized Formaldehyde Solution Dilute
20 mL of 37% formaldehyde solution with 20 mL of
water and neutralize with 0.1 N sodium hydroxide
solution to the phenolphthalein endpoint.
10.3 Chloride Mix 2.2 mL (2.5 g) of sample with
20 mL of water containing 0.5 g of boric acid. Add 1
mL of nitric acid and 1 mL of silver nitrate reagent
solution, and allow to stand for 5 minutes. Any
turbidity produced should be no greater than that
BUFFERED OXIDE ETCHANTS SEMI C23-0301 © SEMI 1981, 20013
produced when 0.01 mg of chloride ion (Cl) is treated
as the sample.
10.4 Nitrate To 2 mL of water in a white plastic
beaker, add 0.9 mL (1g) of sample, 1 mL of sulfuric
acid, 0.05 mL of 0.01 N (0.002 M) potassium
permanganate, mix, and decolorize with sodium
arsenite reagent solution. Dilute to 50 mL with brucine
sulfate reagent solution and mix. Heat the solution in a
preheated (boiling water) bath for 10 minutes. Cool
rapidly in an ice bath to room temperature. The yellow
color of the sample should be no greater than that
produced when 0.01 mg of nitrate ion (NO
3
) is treated
as the sample.
10.5 Phosphate To a 9 mL (10 g) sample in a
platinum dish, add 1 mL of sodium carbonate reagent
solution and 40 mL of nitric acid. Evaporate carefully,
to prevent spattering, to near dryness. Cool, wash down
the sides of the dish with 5 mL of nitric acid, and
evaporate to dryness. Repeat the evaporation with nitric
acid two times to ensure complete removal of all the
fluoride. To the cooled dish, add 25 mL of 0.5 N
sulfuric acid to dissolve the residue, warming if
necessary. Cool, transfer to a color comparison tube,
and add 1 mL of ammonium molybdate reagent
solution, 1 mL of p-(methylamino)phenol sulfate
reagent solution, and allow to stand at room
temperature for 2 hours. Any blue color should be no
greater than that produced when 0.01 mg of phosphate
ion (PO
4
) is treated as the sample.
10.6 Sulfate To 23 mL (25 g) of sample, add 10 mL
of sodium carbonate reagent solution and heat gently
until sample has been volatilized. To the residue, add 5
mL of hydrochloric acid and evaporate to dryness in a
hood. Dissolve the residue in 10 mL of water and 1 mL
of dilute hydrochloric acid (1 + 19); filter if necessary.
Add 1 mL of barium chloride reagent solution, mix, and
allow to stand for 10 minutes. Any turbidity developed
should be no greater than that produced when 0.05 mg
of sulfate ion (SO
4
) solution is treated as the sample.
10.7 Trace Metals Analysis
10.7.1 The following method has given satisfactory
results in determining metal ion impurities at the values
specified for each of the following metals: aluminum
(Al), antimony (Sb), arsenic (As), boron (B), calcium
(Ca), chromium (Cr), copper (Cu), gold (Au), iron (Fe),
lead (Pb), magnesium (Mg), manganese (Mn), nickel
(Ni), potassium (K), silver (Ag), sodium (Na), tin (Sn),
titanium (Ti), and zinc (Zn). Alternate methods may be
used as long as appropriate studies demonstrate a
recovery between 75–125% of a known sample spike
for half of the value of each specified element.
10.7.2 Special Reagents
10.7.2.1 Nitric Acid, Ultrapure Use nitric acid
specified for low metal ion content.
10.7.2.2 4% Nitric Acid Solution Dilute 40 mL of
ultrapure nitric acid to 1 L using water meeting the
criteria for Type E1.1 in ASTM D5127.
10.7.2.3 Water The water used for all the dilution,
calibration, and standards should meet at a minimum
the criteria for Type E1.1 in ASTM D5127 in regard to
cation analysis.
10.7.2.4 Indium Internal Standard Make up a
indium internal standard solution to a concentration of
20 µg/mL (ppm) from an appropriate concentrated
indium standard solution.
10.7.3 Sample Preparation
10.7.3.1 In a clean environment, weigh 10.0 g sample
into a cleaned Teflon beaker and evaporate the sample
on a 250°C hotplate to near dryness. Carefully add 1
mL of the ultrapure nitric and 3 mL of water and gently
warm for several minutes. Cool to room temperature,
add 25 µL of the indium internal standard, and dilute
with Type E1.1 water to a final weight of 25.0 g.
10.7.4 Analysis
10.7.4.1 Using the prepared solutions and blanks,
analyze sodium, potassium, calcium, and iron by
graphite furnace atomic absorption (GFAA) and the
remaining elements by inductively coupled plasma
mass spectrometry (ICP/MS). For calibration, the
standards are made up in 4% nitric acid solution with
final concentration of 20 ng/g of the indium internal
standard. Run a reagent blank.
11 Grade 3 Procedures
11.1 This section does not apply to this chemical.
12 Grade 4 Procedures
12.1 This section does not apply to this chemical.
13 Grade 5 Procedures
13.1 This section does not apply to this chemical.
14 VLSI Grade Procedures
14.1 This section does not apply to this chemical.
15 Tier A Procedures
15.1 This section does not apply to this chemical.
16 Tier B Procedures
16.1 This section does not apply to this chemical.
SEMI C23-0301 © SEMI 1981, 2001 BUFFERED OXIDE ETCHANTS4
17 Tier C Procedures
17.1 This section does not apply to this chemical.
18 Tier D Procedures
18.1 This section does not apply to this chemical.
Table 1 Impurity Limits and Other Requirements for Buffered Oxide Etchants
Previous SEMI Reference # C2.2-95 C7.23-0697
Grade 1 Grade 2
(Specification) (Specification)
Chloride (Cl) -- 4 ppm max
Nitrate (NO
3
) -- 10 ppm max
Phosphate (PO
4
) -- 1 ppm max
Sulfate (SO
4
) -- 2 ppm max
Aluminum (Al) 0.2 ppm max 10 ppb max
Antimony (Sb) -- 10 ppb max
Arsenic (As) -- 10 ppb max
Arsenic and Antimony (as As) 0.03 ppm max --
Boron (B) 0.2 ppm max 20 ppb max
Calcium (Ca) 0.2 ppm max 10 ppb max
Chromium (Cr) 0.1 ppm max 5 ppb max
Copper (Cu) 0.1 ppm max 5 ppb max
Gold (Au) 0.3 ppm max 10 ppb max
Iron (Fe) 0.2 ppm max 5 ppb max
Lead (Pb) 0.3 ppm max 10 ppb max
Magnesium (Mg) 0.2 ppm max 10 ppb max
Manganese (Mn) 0.2 ppm max 10 ppb max
Nickel (Ni) 0.2 ppm max 10 ppb max
Potassium (K) 0.3 ppm max 5 ppb max
Sodium (Na) 0.3 ppm max 5 ppb max
Tin (Sn) 0.3 ppm max 10 ppb max
Titanium (Ti) 0.3 ppm max 10 ppb max
Zinc (Zn) 0.3 ppm max 5 ppb max
Particles in bottles:
size, #/mL
1.0 µm, 25 max 0.5 µm, 150 max
NOTICE: SEMI makes no warranties or representations as to the suitability of the standards set forth herein for any
particular application. The determination of the suitability of the standard is solely the responsibility of the user.
Users are cautioned to refer to manufacturer’s instructions, product labels, product data sheets, and other relevant
literature respecting any materials mentioned herein. These standards are subject to change without notice.
The user’s attention is called to the possibility that compliance with this standard may require use of copyrighted
material or of an invention covered by patent rights. By publication of this standard, SEMI takes no position
respecting the validity of any patent rights or copyrights asserted in connection with any item mentioned in this
standard. Users of this standard are expressly advised that determination of any such patent rights or copyrights, and
the risk of infringement of such rights, are entirely their own responsibility.