00197674-01-UM-E-Series-EN-05-2015 - 第113页
User manual SIPLACE E 3 Technical data and assemblies From software version SC 708.0 05/2015 Edition 3.4 Overviews of the modules 113 3.4.2 Overview of SIPLACE E single sided assemblies 3 3 Fig. 3.4 - 2 SIPLACE E single …

3 Technical data and assemblies User manual SIPLACE E
3.4 Overviews of the modules From software version SC 708.0 05/2015 Edition
112
3.4 Overviews of the modules
3.4.1 Overview of SIPLACE E double sided assemblies
3
3
Fig. 3.4 - 1 SIPLACE E double sided machine - overview of assemblies
(1) Basic module
(2) Reject bin
(3) Stationary cameras (optional)
(4) Monitor with keyboard (2x) on location 2 (optional)
(5) Location 2 with COT insert, tape cutter, empty tape duct
(6) Gantry with placement head (according to the configuration)
(7) PCB conveyor (single conveyor)
(8) Monitor with keyboard (2x) at location 1
(9) Changeover table at location 1
(T) Direction of PCB transport
(1)
(6)
(7)
(8)
(9)
(4)
(5)
(3)
(2)

User manual SIPLACE E 3 Technical data and assemblies
From software version SC 708.0 05/2015 Edition 3.4 Overviews of the modules
113
3.4.2 Overview of SIPLACE E single sided assemblies
3
3
Fig. 3.4 - 2 SIPLACE E single sided machine - overview of assemblies
(1) Basic module
(2) Reject bin
(3) Stationary cameras (optional)
(4) Gantry with placement head (according to the configuration)
(5) PCB conveyor (single conveyor)
(6) Monitor with keyboard at location 1
(7) Changeover table at location 1
(T) Direction of PCB transport
(1)
(4)
(5)
(6)
(7)
(2)
(3)

3 Technical data and assemblies User manual SIPLACE E
3.5 Placement head From software version SC 708.0 05/2015 Edition
114
3.5 Placement head
3.5.1 SIPLACE CP14 for very high speed placement
Item no. 03109887-xx, SIPLACE CP14 (without camera)
Item no. 03105195-xx, Component camera, type 23 GigE
3
Fig. 3.5 - 1 SIPLACE CP14 - function group part 1
(1) DP drive, 14 drives
(2) Pressure control valve
(3) Z motor (linear motor)
(4) Return cylinder
(5) Line for the exhaust air from the pressure control valve (2)
(6) Compressed air connection for 14 Venturi nozzles in the pickup/placement and holding circuit
(1)
(2)
(3)
(4)
(5)
(6)