5 Working with the machine User manual SIPLACE E 5.4 Switching off the station From software version SC 708.0 05/ 2015 Edition 204 5.3.4 Action performed by machine start button The actio n performed by the st art button…

100%1 / 308
User manual SIPLACE E 5 Working with the machine
From software version SC 708.0 05/2015 Edition 5.3 Switching on the Machine
203
5
Fig. 5.3 - 1 "Production" view after loading the station software (example of SIPLACE E1 shown)
The status field (see section 5.6.1, page 207) shows the current status of the station and the action
to be performed.
Press the start button on the HMI when you see the request "Press the Start button to begin
production".
A reference run will be performed. After completion of this reference run, the station is ready
for operation.
The icon will be shown in the working area of the user interface (enabled).
5 Working with the machine User manual SIPLACE E
5.4 Switching off the station From software version SC 708.0 05/2015 Edition
204
5.3.4 Action performed by machine start button
The action performed by the start button can be set.
Open the Check sensors and functions view (see section 5.6.3, page 208).
The following settings are possible:
Start production automatically 5
Standard setting.
Pressing the start button automatically begins the production process.
Do not change production status 5
This is used, for example, to calibrate and test the machine
Pressing the start button simply closes the electricity circuit; production is not started immediately.
5
5.4 Switching off the station
To switch off the station, proceed as follows:
End all placement procedures, so that there are no more boards in the machine.
Check whether the Z axes of all placement heads are in their uppermost end positions.
Check whether there are still components on the placement heads and remove these.
Close the station computer software in the view
Set settings and options --> Check and set machine settings --> Shut down
machine...
Once the computer has been shut down, switch off the station at the main switch.
CAUTION
Machine functions can be directly started via the GUI, irrespective of the start button set
-
ting. If the electrical circuit has already been closed, you do not need to confirm with the
start button again.
User manual SIPLACE E 5 Working with the machine
From software version SC 708.0 05/2015 Edition 5.5 Opening and closing the protective covers
205
5.5 Opening and closing the protective covers
The protective covers are electrically and mechanically locked and cannot be opened during op
-
eration.
Opening the protective covers 5
Press the stop button to open the protective cover.
A message is issued at the station software stating that the protective covers can be
opened.
The protective covers are mechanically released and can be opened.
Closing the protective covers 5
Close the protective covers.
Press the start button.
The protective covers are mechanically locked and can no longer be opened.